Appendix B

Side B of the VP1000 A / B Sheet

START-UP/NEW INSTALLATION/ WARRANTY/ ANNUAL TESTING FORM (Rev. 10/07) 

HEALY VP1000 VACUUM PUMP  

Date___________________

BOTH SIDES OF THIS TEST FORM MUST BE COMPLETED FOR NEW INSTALLATIONS

•   Start-up / New installations – Complete Sections 3, 4, 5 and 6 of SIDE B.  Submit  forms to 

Healy Systems.

•   Warranty Service or Annual Testing – Conduct the appropriate tests specified on SIDE B.  

Submit Forms to Healy Systems.

SIDE B

Warranty Service

Complete Troubleshooting Sections 

 

B-1 and B-2

Start-up/ New Installations/ Annual 

Testing 

Complete Sections

B-3 through B-6

B-1

Control Module Fault Light                       

                           (Circle one)               Flashing  (LED)                          Steady  (LED)     

              

1.  All fault conditions require removal and cleaning or replacement of the rotor and vanes located inside the 

vacuum pumps round front cover assembly. Use the 

VP1000 ROTOR & VANE SERVICE AND REPLACEMENT 

GUIDE 

in the applicable dispenser retrofit manual of the ARB Approved Installation, Operation and Maintenance 

Manual for Executive Orders VR-201 and VR-202. 

2.  Clean all surfaces including vanes, rotor, rotor housing, and cover assembly. 

3.  Manually spin and inspect the motor shaft for bearing wear before re-installing the rotor kit.

4.  Replace motor when bearings or shaft are damaged or worn.

5.   Check O-ring seal before replacing rotor cover assembly.

B-2

Re-Assemble / Reset Vacuum Pump and Module. (Power must be removed from both the vacuum pump and the 

module for 20 seconds to reset the system

) using the power reset switch on the MC100 module.

B-3

1.  Install 0-100 inch water column (“ wc) vacuum mechanical gauge at the VP1000 test port.

2.  Authorize the dispenser for fueling.  The VP1000 will begin to run.

3.  Close the ball valve at the pump inlet.  

4.  Record the initial vacuum reading on the gauge – observe and record the final vacuum reading after 60 

seconds.

5.  Open the ball valve at the pump inlet.

6.  Leaks must be repaired when the vacuum reading falls more than 4” wc in 60 seconds.

7.  Retest until all leaks have been repaired.

8.  Record data in Section B-4.

Note: If the initial vacuum reading is less than 60” wc, it could indicate a problem with the VP1000.  

Remove the dispenser from service.  Use the troubleshooting section of the manual to investigate 

problem or contact the FFS Technical Help Desk at 800-984-6266 for assistance.

Dispenser V

apor Line

Integrity 

Test

B-4

VACUUM TEST Using VP1000 as 

vacuum source

Initial Vacuum  test reading (“ wc)

Vacuum test reading after 60 sec. 

(“ wc)

B-5

With one side of the dispenser authorized (VP1000 running) and the ball valve at the pump inlet open, dispense 

in handheld position a minimum of 0.5 gallons of fuel into a vehicle or test tank.  Record the vacuum level while 

dispensing.  Repeat test for the other side of the dispenser. 

1.   Side “A”   Dispensing Vacuum  ____________” wc

2.   Side “B”   Dispensing Vacuum  ____________” wc

Note:  If the dispensing vacuum is less than 60” wc, remove the dispenser from service. See the trouble-

shooting section of the manual or contact FFS Technical Help Desk at 800-984-6266 for assistance.

Dispenser  Vacuum 

Test

B-6

Test the VP1000 Vacuum Pump for normal operation.  Use the 6 step procedure titled, “Testing the VP1000 

Vacuum Pump for normal operation using the following test procedure:” in Section 1.1 (Weekly Inspection and 

Testing) of the Healy Systems Scheduled Maintenance document in the ARB Approved Installation, Operation 

and Maintenance Manual for the Healy Phase II EVR System not Including ISD.  This is to verify that the pump 

recognizes when both sides of the dispenser are activated for fueling.

Does the VP1000 Vacuum Pump change speeds (audible increase) when both sides are activated for fueling?     

                                                                            Yes    No

If the answer is no, 

use the troubleshooting section of the manual to investigate problem or contact the 

FFS Technical Help Desk at 800-984-6266 for assistance. 

       

Audible Increase

Test

Repairs - Comments

To Obtain Returned Materials Authorization number (RMA#)  Call 800-984-6266

Forms can be faxed to Franklin Fueling Systems Customer Service at 800-225-9787

Note:  See CARB Executive Order VR-201 for complete installation, operation, and maintenance (IOM) details.

Summary of Contents for VP1000-5

Page 1: ...anklin Fueling Systems 3760 Marsh Rd Madison WI 53718 USA Tel 1 608 838 8786 800 225 9787 Fax 1 608 838 6433 www franklinfueling com Manual Revision Date Changes from Previous Revision 405291001 2 Mar...

Page 2: ...Under Current Fault Troubleshooting 8 Section Four Over Current Fault Troubleshooting 9 Section Five VP1000 5 Performance Testing 10 Appendix A VP1000 5 Installation and Testing 12 Appendix B Side B...

Page 3: ...environment or by using any other reasonable means available to ensure the safety of service personnel Follow all federal state and local laws governing the installation of this equipment When no oth...

Page 4: ...202 A Healy Phase II System outside California in North America includes one VP1000 5 vacuum pump per dispenser and the appropriate Healy hanging hardware including Model 800 nozzles at each fueling...

Page 5: ...nstalled per dispenser to accommodate the vapor recovery needs for both sides of the dispenser When the dispenser is authorized the MC100 1 will activate the VP1000 5 simultaneously and run at a low s...

Page 6: ...oduct The MC100 1 s solenoid disconnect relay provides interruption of the solenoid valve neutral circuit when the VP1000 5 is in a fault state Figure 2 describes the meanings of the indicator lights...

Page 7: ...Performance Testing in Section 5 Is a fault condition present on the MC100 1 Reset the system by removing the white reset plug on the MC100 1 for a minimum of 20 seconds Re insert the white reset plu...

Page 8: ...er VR 201 No Verify the performance of the VP1000 5 per B 5 of the A B sheet Refer to Appendix B Yes Is the vacuum level produced by the VP1000 5 between 60 90 WC Disconnect the white reset plug on th...

Page 9: ...the VP1000 5 between 60 90 WC Disconnect the white reset plug on the MC100 1 Remove the VP1000 5 front cover to evaluate the rotor vanes for wear and or damage Refer to Appendix C Check for debris and...

Page 10: ...mance of the VP1000 5 per B 5 of the A B sheet Refer to Appendix B Is the vacuum level produced by the VP1000 5 between 60 and 90 WC Disconnect the white reset plug on the MC100 1 Remove the VP1000 5...

Page 11: ...e VP1000 5 increase from low to high speed when both sides of the dispenser are activated Verify the wiring of the MC100 1 Refer to Appendix E No Retest Continued from previous page Remove the vacuum...

Page 12: ...ow shows a vacuum gauge face with the acceptable vacuum level highlighted when measured with a VP1000 5 vacuum pump The acceptable vacuum level from the VP1000 5 is between 60 and 90 WC Readings of 3...

Page 13: ...est until all leaks have been repaired 8 Record data in Section B 4 Note If the initial vacuum reading is less than 60 wc it could indicate a problem with the VP1000 Remove the dispenser from service...

Page 14: ...e damage use a lint free cloth with isopropyl alcohol to clean the rotor and vanes 9 Using a lint free cloth with isopropyl alcohol thoroughly clean the inside of the pump ring and rear of the pump ca...

Page 15: ...activate Note For unihose dispensers conduct individual tests for each product grade on each side of the dispenser to ensure that the same LED activates for all grades on the same side If the other L...

Page 16: ...C should be measured between either red and orange wires When no fault is present 5VDC should be measured between purple and orange wires When fault is present 0VDC should be measured between purple a...

Page 17: ...ACH and JUMPER terminals to create a short 3 With the jumper wire in place re insert the white reset plug The yellow power light should now be illuminated 4 Authorize a nozzle on Side A of the dispens...

Page 18: ...P1000 MC100 interface check one Red Light is FLASHING over current Red Light is SOLID under current Red Light is OFF Dispenser Integrity inches of water column Starting Vacuum ________ Ending Vacuum _...

Page 19: ...19 2012 FFS 405291001 Rev2...

Reviews: