Thank you for purchasing the CompX RegulatoR. The RegulatoR is an 

innovative solution for locking cabinet doors and drawers. It can mount to 

cabinet doors or drawers with a material thickness of 1/32” to 1-7/16”. 

Powered by 2-AAA batteries (included), RegulatoR operates using a 4 to 8 digit 

code. Operation is simple: type a valid code and press ENTER.  Then just turn 

the lever to the locked or unlocked position.  

RegulatoR is easy to install, and offers: 

 

Programmable user and supervisor codes 

 

Programmable modes of operation 

 

Programmable reset features 

RegulatoR is intended for interior use only.  

 

Operating Temperature: 50°F – 120°F (10°C – 48°C) 

Note: It is strongly recommended that batteries be replaced on an annual basis.  

In the event the batteries should die, they can be replaced via the external battery 

compartment. 

 RegulatoR, Keyless Locking   15 

   

Summary of Contents for Lock

Page 1: ...xes 18671 18676 1 Step 1 Clean surface and peel the protective backing from the Receiving Base 2 3 4 Step 2 Place the Receiving Base in the Wall Mount or on countertop cart top or shelves Step 3 Press firmly for several seconds to attach the Receiving Base Step 4 Loosely drive the screw into the desired location on the wall or cabinet Screws are not provided ...

Page 2: ...ce level tighten screws into the remaining holes 7 8 9 Step 7 Push the locking box onto the Receiving Base Continue pushing until the locking box clicks into place Step 8 Unlock the box Step 9 Pull up of the white button in the middle of the locking box While pulling up on the button pull the entire box forward off of the Receiving Base 5 Step 5 Place a level on top of the Wall Mount ...

Page 3: ... mode There is a 10 second programming time limit between each step If RegulatoR times out or error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 8 a To turn Security Timeout ON type 11 and then press ENTER OR b To turn Security Timeout OFF type 10 and then press ENTER 2 If successful the green indicator light will i...

Page 4: ...rogramming or press 9 and then ENTER to exit programming RegulatoR Keyless Locking 6 CompX RegulatoR is offered with Self Lock featuring SlamCAM If your lock is the Self Lock version follow the directions below to unlock and lock the RegulatoR To operate the Self Lock version of RegulatoR Type a valid code press ENTER and rotate knob clockwise 90 hold knob until door or drawer is open Release knob...

Page 5: ...es out or an error is made programming will end and you will need to enter programming mode again 1 Place KEDL into programming mode a To turn Single Use Mode ON type 51 and then press ENTER OR b To return to Standard Mode type 50 and then press ENTER 2 If successful the green indicator light will illuminate for 1 second Note Returning to Standard Mode will reset the factory user default code 1234...

Page 6: ...Call Free 1 800 848 1633 Fax Free 1 800 447 2923 Web GoHCL com Email hcl GoHCL com Health Care Logistics Inc 2014 INSTRUCTIONS FOR KEDL Lock digit urn sis attery RegulatoR Keyless Locking 15 ...

Reviews: