INSTRUCTIONS FOR
KEDL Lock
KEDL is offered with Self Lock featuring SlamCAM. If your lock
is the Self Lock version, follow the directions below to unlock
and lock the KEDL:
The KEDL is offered in a Manual Lock version. If your lock is the
Manual Lock version follow the directions below to unlock and
lock the KEDL.
KEDL Programming Mode
To enter programming mode you must know the supervisor
code. The default supervisor code is 12345. Once in
programming mode, multiple changes can be made prior to
exiting programming.
There is a 10 second programming time limit between each step.
If KEDL times out or an error is made, programming will end
and you will need to enter programming mode again.
1. Lock must be in the locked position prior to entering
programming mode.
2. Type supervisor code and press ENTER.
3. Turn knob clockwise 90° to the unlocked position and press
and hold ENTER for 3 seconds (yellow indicator light will
illuminate).
· If product is Self Lock with the SlamCAM feature you can now
let go of the knob.
4. With the yellow indicator light illuminated, programming can
begin.
Changing the User Code
To change the user code, follow the steps on page 8 to enter
programming mode.
The factory default user code is 1234 (User codes must be 4 to 8
digits in length.)
There is a 10 second programming time limit between each step.
If KEDL times out or an error is made, programming will end
and you will need to enter programming mode again.
1. Place KEDL into programming mode (see page 8).
2. Press 1 and then press ENTER.
3. Type the current user code and press ENTER.
4. Type the new user code and press ENTER.
5. Retype the new user code and press ENTER.
6. If successful, the green indicator light will illuminate for 1
second.
Continue programming or press 9 and then ENTER to exit
programming.
RegulatoR, Keyless Locking 6
CompX RegulatoR is offered with Self Lock featuring SlamCAM. If your lock
is the Self Lock version, follow the directions below to unlock and lock the
RegulatoR:
To operate the Self Lock version of RegulatoR:
Type a valid code, press ENTER and rotate knob
clockwise 90°, hold knob until door or drawer is
open. Release knob, RegulatoR knob will return
to the locked position. Door or drawer can be
closed at any time.
RegulatoR, Keyless Locking 11
CompX RegulatoR features several modes of operation. These functions can be
changed using the following instructions with a valid supervisor code.
Programming Single Use Mode / Standard Mode
Single Use Mode allows for a revolving user code so multiple people may use
the lock without having to reprogram the RegulatoR each time.
Note: This mode cannot be used with Self Lock with SlamCAM.
Standard Mode RegulatoR operates with a fixed code. To change the code,
follow the Changing the User Code steps on page 9.
To change the RegulatoR to Single Use or Standard Mode, follow the steps on
page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
a. To turn Single Use Mode “ON”: type 51 and then press
ENTER.
OR
b. To return to Standard Mode: type 50 and then press ENTER.
2. If successful, the green indicator light will illuminate for 1 second.
Note: Returning to Standard Mode will reset the factory user default code
(1234).
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR, Keyless Locking 10
Changing the Supervisor Code
To change the supervisor code, follow the steps on page 8 to enter programming
mode.
The factory default supervisor code is 12345 (supervisor codes must be 4 to 8
digits in length.)
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
2. Press 2 and then press ENTER.
3. Type the current supervisor code and press ENTER.
4. Type the new supervisor code and press ENTER.
5. Retype the new supervisor code and press ENTER.
6. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR features a reset code which will restore the default supervisor code
and user code. RegulatoR was shipped with reset stickers; one attached to the
back of the RegulatoR and an extra sticker that should be saved in a safe and
secure location for future reference.
To restore the factory default supervisor and user code, type the Reset Code
assigned to the RegulatoR and press ENTER.
RegulatoR, Keyless Locking 7
CompX RegulatoR is offered in a Manual Lock version. If your lock is the
Manual Lock version follow the directions below to unlock and lock the
RegulatoR.
To operate Manual Lock version of
RegulatoR:
To unlock, type a valid code, press
ENTER and rotate knob clockwise 90°.
To lock, rotate knob 90° counter
clockwise.