background image

Call Free: 1.800.848.1633 • Fax Free: 1.800.447.2923

 Web: GoHCL.com • Email: [email protected]

© Health Care Logistics, Inc. 2014

INSTRUCTIONS FOR

 

KEDL Lock

KEDL is offered with Self Lock featuring SlamCAM. If your lock 

is the Self Lock version, follow the directions below to unlock 

and lock the KEDL:

The KEDL is offered in a Manual Lock version. If your lock is the 

Manual Lock version follow the directions below to unlock and 

lock the KEDL.

KEDL Programming Mode

To enter programming mode you must know the supervisor 

code. The default supervisor code is 12345. Once in 

programming mode, multiple changes can be made prior to 

exiting programming.

There is a 10 second programming time limit between each step. 

If KEDL times out or an error is made, programming will end 

and you will need to enter programming mode again.

1.  Lock must be in the locked position prior to entering 

programming mode.

2.  Type supervisor code and press ENTER.

3.  Turn knob clockwise 90° to the unlocked position and press 

and hold ENTER for 3 seconds (yellow indicator light will 

illuminate).

· If product is Self Lock with the SlamCAM feature you can now 

let go of the knob.

4.  With the yellow indicator light illuminated, programming can 

begin.

Changing the User Code

To change the user code, follow the steps on page 8 to enter 

programming mode.

The factory default user code is 1234 (User codes must be 4 to 8 

digits in length.)

There is a 10 second programming time limit between each step. 

If KEDL times out or an error is made, programming will end 

and you will need to enter programming mode again.

1.  Place KEDL into programming mode (see page 8).

2.  Press 1 and then press ENTER.

3.  Type the current user code and press ENTER.

4.  Type the new user code and press ENTER.

5.  Retype the new user code and press ENTER.

6.  If successful, the green indicator light will illuminate for 1 

second.

Continue programming or press 9 and then ENTER to exit 

programming.

 RegulatoR, Keyless Locking   6 

CompX RegulatoR is offered with Self Lock featuring SlamCAM.  If your lock 

is the Self Lock version, follow the directions below to unlock and lock the 

RegulatoR: 

To operate the Self Lock version of RegulatoR: 

Type a valid code, press ENTER and rotate knob 

clockwise 90°, hold knob until door or drawer is 

open. Release knob, RegulatoR knob will return 

to the locked position. Door or drawer can be 

closed at any time.  

 RegulatoR, Keyless Locking   11 

CompX RegulatoR features several modes of operation. These functions can be 

changed using the following instructions with a valid supervisor code.   

Programming Single Use Mode / Standard Mode 

Single Use Mode allows for a revolving user code so multiple people may use 

the lock without having to reprogram the RegulatoR each time.  

Note: This mode cannot be used with Self Lock with SlamCAM. 

Standard Mode RegulatoR operates with a fixed code. To change the code, 

follow the Changing the User Code steps on page 9. 

To change the RegulatoR to Single Use or Standard Mode, follow the steps on 

page to enter programming mode. 

There is a 10 second programming time limit between each step. If RegulatoR 

times out or an error is made, programming will end and you will need to enter 

programming mode again. 

1. Place RegulatoR into programming mode (see page 8).

a. To turn Single Use Mode “ON”:  type 51 and then press 

ENTER.

OR 

b. To return to Standard Mode: type 50 and then press ENTER.

2. If successful, the green indicator light will illuminate for 1 second. 

Note: Returning to Standard Mode will reset the factory user default code 

(1234).  

Continue programming or press 9 and then ENTER to exit programming. 

 RegulatoR, Keyless Locking   10 

Changing the Supervisor Code 

To change the supervisor code, follow the steps on page 8 to enter programming 

mode. 

The factory default supervisor code is 12345 (supervisor codes must be 4 to 8 

digits in length.) 

There is a 10 second programming time limit between each step. If RegulatoR 

times out or an error is made, programming will end and you will need to enter 

programming mode again. 

1. Place RegulatoR into programming mode (see page 8).

2. Press 2 and then press ENTER

3. Type the current supervisor code and press ENTER

4. Type the new supervisor code and press ENTER

5. Retype the new supervisor code and press ENTER.  

6. If successful, the green indicator light will illuminate for 1 second. 

Continue programming or press 9 and then ENTER to exit programming. 

RegulatoR features a reset code which will restore the default supervisor code 

and user code. RegulatoR was shipped with reset stickers; one attached to the 

back of the RegulatoR and an extra sticker that should be saved in a safe and 

secure location for future reference. 

To restore the factory default supervisor and user code, type the Reset Code 

assigned to the RegulatoR and press ENTER

 RegulatoR, Keyless Locking   7 

CompX RegulatoR is offered in a Manual Lock version. If your lock is the 

Manual Lock version follow the directions below to unlock and lock the 

RegulatoR.  

To operate Manual Lock version of 

RegulatoR: 

To unlock, type a valid code, press 

ENTER and rotate knob clockwise 90°.  

To lock, rotate knob 90° counter 

clockwise.  

Summary of Contents for Lock

Page 1: ...xes 18671 18676 1 Step 1 Clean surface and peel the protective backing from the Receiving Base 2 3 4 Step 2 Place the Receiving Base in the Wall Mount or on countertop cart top or shelves Step 3 Press firmly for several seconds to attach the Receiving Base Step 4 Loosely drive the screw into the desired location on the wall or cabinet Screws are not provided ...

Page 2: ...ce level tighten screws into the remaining holes 7 8 9 Step 7 Push the locking box onto the Receiving Base Continue pushing until the locking box clicks into place Step 8 Unlock the box Step 9 Pull up of the white button in the middle of the locking box While pulling up on the button pull the entire box forward off of the Receiving Base 5 Step 5 Place a level on top of the Wall Mount ...

Page 3: ... mode There is a 10 second programming time limit between each step If RegulatoR times out or error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 8 a To turn Security Timeout ON type 11 and then press ENTER OR b To turn Security Timeout OFF type 10 and then press ENTER 2 If successful the green indicator light will i...

Page 4: ...rogramming or press 9 and then ENTER to exit programming RegulatoR Keyless Locking 6 CompX RegulatoR is offered with Self Lock featuring SlamCAM If your lock is the Self Lock version follow the directions below to unlock and lock the RegulatoR To operate the Self Lock version of RegulatoR Type a valid code press ENTER and rotate knob clockwise 90 hold knob until door or drawer is open Release knob...

Page 5: ...es out or an error is made programming will end and you will need to enter programming mode again 1 Place KEDL into programming mode a To turn Single Use Mode ON type 51 and then press ENTER OR b To return to Standard Mode type 50 and then press ENTER 2 If successful the green indicator light will illuminate for 1 second Note Returning to Standard Mode will reset the factory user default code 1234...

Page 6: ...Call Free 1 800 848 1633 Fax Free 1 800 447 2923 Web GoHCL com Email hcl GoHCL com Health Care Logistics Inc 2014 INSTRUCTIONS FOR KEDL Lock digit urn sis attery RegulatoR Keyless Locking 15 ...

Reviews: