Call Free: 1.800.848.1633 • Fax Free: 1.800.447.2923
Web: GoHCL.com • Email: [email protected]
© Health Care Logistics, Inc. 2014
INSTRUCTIONS FOR
KEDL Lock
The KEDL is offered in two versions:
Manual Lock and Self Lock. Contents will vary depending on the
version.
Contents – Manual Lock Version:
Manual KEDL Assembly
2 AAA alkaline batteries
1 Offset locking cam / 1 Straight locking cam
FlexaCam adapters
Mounting hardware
Contents – Self Lock Version:
Self Locking KEDL assembly featuring SlamCAM
2 AAA alkaline batteries
SlamCAM spacer discs
Mounting hardware
Each lock contains 2 green stickers that are needed for resetting
KEDL. In the event KEDL needs reset, one green sticker is placed
on the back of the device. The remaining green sticker should
be saved in a safe and secure location for future reference. HCL
keeps no record of this.
Care and Cleaning
To clean the KEDL surface, apply non-acid based cleaner to a
clean cotton cloth; do not spray cleaner directly on the KEDL.
Wipe down keypad and its respective housing surfaces of excess
cleaner.
Powering Up and Battery Installation
KEDL is shipped with two AAA batteries. While KEDL
features a low battery indicator, annual battery replacement is
recommended. Mixing batteries of different chemistries could
damage the KEDL resulting
in lock failure.
To power up KEDL, remove the red tag. Lock is now ready for
use.
A Phillips head screw driver will be required to remove the
battery cover. (Not Included)
To change batteries:
1. Loosen the retaining screw.
2. Remove battery cover.
3. Press CLEAR 5 times.
4. Insert new batteries as
shown in the illustration.
5. Reinstall battery cover,
tighten retaining screw.
RegulatoR, Keyless Locking 4
Powering Up and Battery Installation
CompX RegulatoR is shipped with two AAA batteries. While RegulatoR
features a low battery indicator, annual battery replacement is recommended.
Mixing batteries of different chemistries could damage the RegulatoR resulting
in lock failure.
To power up RegulatoR, remove the red tag. Lock is now ready for use.
A T-15 pin in head Torx
®
(6-lobe) will be required to remove the battery cover.
(Not Included)
To change batteries:
1. Loosen the retaining
screw.
2. Remove battery cover.
3. Press CLEAR 5 times.
4. Insert new batteries as
shown in the illustration.
5. Reinstall battery cover,
tighten retaining screw.
RegulatoR, Keyless Locking 13
Programming Security Timeout ON / Security Timeout OFF
Warning: Security Timeout ON will disable the RegulatoR from use for 5
minutes when 5 invalid attempts to unlock RegulatoR occur. During this time,
RegulatoR will not unlock with either the valid user or supervisor code.
To change the RegulatoR to Security Timeout ON or OFF, follow the steps on
page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode see page 8).
a. To turn Security Timeout ON, type 11 and then press
ENTER.
OR
b. To turn Security Timeout OFF, type 10 and then press
ENTER.
2. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
Programming – Introduction
KEDL is easy to program and operate. Type the user code
(factory default 1234) and press ENTER to lock or unlock the
cabinet.
The supervisor can change operating codes, modes and restore
lock settings. While KEDL is easy to program, we highly
recommend reading the complete programming instructions
prior to making any changes. Remember to keep track of any
programming changes.
Button locations, indicator lights and knob referenced in the
programming instructions are shown below.
RegulatoR, Keyless Locking 12
Programming Single Use Timeout ON / Single Use Timeout OFF
Warning: Manual Lock - Single Use Timeout ON is a feature to prevent users
from occupying a shared use locker or cabinet for a prolonged period of time.
Turning this feature on will disable the user code after a programmable amount
of time. After this time elapses, RegulatoR and can only be opened with the
supervisor code.
To change the RegulatoR to Single Use Timeout ON or OFF, follow the steps
on page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
a. To set Timeout ON, type 2XX and then press ENTER.
(XX represents a time period from 04 - 12 in whole hours.)
OR
b. To turn Timeout OFF, type 20 and then press ENTER.
3. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR, Keyless Locking 5
Programming – Introduction
CompX RegulatoR is easy to program and operate. Type the user code (factory
default 1234) and press ENTER to lock or unlock the cabinet.
The supervisor can change operating codes, modes and restore lock settings.
While RegulatoR is easy to program, we highly recommend reading the
complete programming instructions prior to making any changes. Remember to
keep track of any programming changes.
Button locations, indicator lights and knob referenced in the programming
instructions are shown below.
CLEAR button erases any key input made in error
Indicator Lights
Green – Indicates button
input and valid code
Yellow - Indicates low
battery or program mode.
Red – Indicates incorrect
entry
Knob is always rotated
clockwise to unlock
ENTER button is used to complete code
and counter clockwise to lock
and begin programming