INSTRUCTIONS FOR

 

KEDL Lock

The KEDL is offered in two versions: 

Manual Lock and Self Lock. Contents will vary depending on the 

version.

Contents – Manual Lock Version:

Manual KEDL Assembly

2 AAA alkaline batteries

1 Offset locking cam / 1 Straight locking cam

FlexaCam adapters

Mounting hardware

Contents – Self Lock Version:

Self Locking KEDL assembly featuring SlamCAM

2 AAA alkaline batteries

SlamCAM spacer discs

Mounting hardware

Each lock contains 2 green stickers that are needed for resetting 

KEDL. In the event KEDL needs reset, one green sticker is placed 

on the back of the device. The remaining green sticker should 

be saved in a safe and secure location for future reference. HCL 

keeps no record of this.

Care and Cleaning

To clean the KEDL surface, apply non-acid based cleaner to a 

clean cotton cloth; do not spray cleaner directly on the KEDL. 

Wipe down keypad and its respective housing surfaces of excess 

cleaner.

Powering Up and Battery Installation

KEDL is shipped with two AAA batteries. While KEDL 

features a low battery indicator, annual battery replacement is 

recommended. Mixing batteries of different chemistries could 

damage the KEDL resulting

in lock failure.

To power up KEDL, remove the red tag. Lock is now ready for 

use.

A Phillips head screw driver will be required to remove the 

battery cover. (Not Included)

To change batteries:

1.  Loosen the retaining screw.

2.  Remove battery cover.

3.  Press CLEAR 5 times.

4.  Insert new batteries as  

shown in the illustration.

5.  Reinstall battery cover,  

tighten retaining screw.

 RegulatoR, Keyless Locking   4 

Powering Up and Battery Installation  

CompX RegulatoR is shipped with two AAA batteries.  While RegulatoR 

features a low battery indicator, annual battery replacement is recommended.  

Mixing batteries of different chemistries could damage the RegulatoR resulting 

in lock failure. 

To power up RegulatoR, remove the red tag. Lock is now ready for use. 

A T-15 pin in head Torx

®

 (6-lobe) will be required to remove the battery cover. 

(Not Included) 

To change batteries:                                                         

   

1. Loosen the retaining  

    screw.   

2. Remove battery cover. 

3. Press CLEAR 5 times. 

4. Insert new batteries as  

    shown in the illustration. 

5. Reinstall battery cover, 

    tighten retaining screw. 

    

  

 RegulatoR, Keyless Locking   13 

Programming Security Timeout ON / Security Timeout OFF 

Warning: Security Timeout ON will disable the RegulatoR from use for 5 

minutes when 5 invalid attempts to unlock RegulatoR occur. During this time, 

RegulatoR will not unlock with either the valid user or supervisor code. 

To change the RegulatoR to Security Timeout ON or OFF, follow the steps on 

page to enter programming mode. 

There is a 10 second programming time limit between each step. If RegulatoR 

times out or error is made, programming will end and you will need to enter 

programming mode again. 

1. Place RegulatoR into programming mode see page 8). 

a. To turn Security Timeout ON, type 11 and then press 

ENTER.

OR 

b. To turn Security Timeout OFF, type 10 and then press 

ENTER

2. If successful, the green indicator light will illuminate for 1 second. 

Continue programming or press 9 and then ENTER to exit programming. 

Programming – Introduction

KEDL is easy to program and operate. Type the user code 

(factory default 1234) and press ENTER to lock or unlock the 

cabinet.

The supervisor can change operating codes, modes and restore 

lock settings. While KEDL is easy to program, we highly 

recommend reading the complete programming instructions 

prior to making any changes. Remember to keep track of any 

programming changes.

Button locations, indicator lights and knob referenced in the 

programming instructions are shown below.

 RegulatoR, Keyless Locking   12 

Programming Single Use Timeout ON / Single Use Timeout OFF 

Warning: Manual Lock - Single Use Timeout ON is a feature to prevent users 

from occupying a shared use locker or cabinet for a prolonged period of time.  

Turning this feature on will disable the user code after a programmable amount 

of time.  After this time elapses, RegulatoR and can only be opened with the 

supervisor code.  

To change the RegulatoR to Single Use Timeout ON or OFF, follow the steps 

on page to enter programming mode. 

There is a 10 second programming time limit between each step. If RegulatoR 

times out or an error is made, programming will end and you will need to enter 

programming mode again. 

1. Place RegulatoR into programming mode (see page 8).

a. To set Timeout ON, type 2XX and then press ENTER.  

(XX represents a time period from 04 - 12 in whole hours.) 

OR 

b. To turn Timeout OFF, type 20 and then press ENTER

3. If successful, the green indicator light will illuminate for 1 second. 

Continue programming or press 9 and then ENTER to exit programming. 

 RegulatoR, Keyless Locking   5 

Programming – Introduction 

CompX RegulatoR is easy to program and operate.  Type the user code (factory 

default 1234) and press ENTER to lock or unlock the cabinet. 

The supervisor can change operating codes, modes and restore lock settings.  

While RegulatoR is easy to program, we highly recommend reading the 

complete programming instructions prior to making any changes. Remember to 

keep track of any programming changes. 

Button locations, indicator lights and knob referenced in the programming 

instructions are shown below. 

                  CLEAR button erases any key input made in error  

                                                                             Indicator Lights    

                                      

Green – Indicates button 

input and valid code 

  

Yellow - Indicates low 

battery or program mode. 

Red – Indicates incorrect 

entry 

Knob is always rotated  

clockwise to unlock 

 

ENTER button is used to complete code  

and counter clockwise to lock 

and begin programming

     

 

          

Summary of Contents for Lock

Page 1: ...xes 18671 18676 1 Step 1 Clean surface and peel the protective backing from the Receiving Base 2 3 4 Step 2 Place the Receiving Base in the Wall Mount or on countertop cart top or shelves Step 3 Press firmly for several seconds to attach the Receiving Base Step 4 Loosely drive the screw into the desired location on the wall or cabinet Screws are not provided ...

Page 2: ...ce level tighten screws into the remaining holes 7 8 9 Step 7 Push the locking box onto the Receiving Base Continue pushing until the locking box clicks into place Step 8 Unlock the box Step 9 Pull up of the white button in the middle of the locking box While pulling up on the button pull the entire box forward off of the Receiving Base 5 Step 5 Place a level on top of the Wall Mount ...

Page 3: ... mode There is a 10 second programming time limit between each step If RegulatoR times out or error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 8 a To turn Security Timeout ON type 11 and then press ENTER OR b To turn Security Timeout OFF type 10 and then press ENTER 2 If successful the green indicator light will i...

Page 4: ...rogramming or press 9 and then ENTER to exit programming RegulatoR Keyless Locking 6 CompX RegulatoR is offered with Self Lock featuring SlamCAM If your lock is the Self Lock version follow the directions below to unlock and lock the RegulatoR To operate the Self Lock version of RegulatoR Type a valid code press ENTER and rotate knob clockwise 90 hold knob until door or drawer is open Release knob...

Page 5: ...es out or an error is made programming will end and you will need to enter programming mode again 1 Place KEDL into programming mode a To turn Single Use Mode ON type 51 and then press ENTER OR b To return to Standard Mode type 50 and then press ENTER 2 If successful the green indicator light will illuminate for 1 second Note Returning to Standard Mode will reset the factory user default code 1234...

Page 6: ...Call Free 1 800 848 1633 Fax Free 1 800 447 2923 Web GoHCL com Email hcl GoHCL com Health Care Logistics Inc 2014 INSTRUCTIONS FOR KEDL Lock digit urn sis attery RegulatoR Keyless Locking 15 ...

Reviews: