background image

H B X   E C O - 0 6 0 0   G e o t h e r m a l   C o n t r o l

V e r s i o n   1 . 0 . 0

 Page 23

Limited Warranty

HBX Controls warrants each of its products to be free from defects in workmanship and materials under normal use and 

service for a period of 24 months from date of manufacture or 12 months from date of purchase from an HBX Authorized 

Dealer, if within the above documented period after date of manufacture.
If the product proves to be defective within the applicable warranty period, HBX on its sole discretion will repair or replace 

said product.  Replacement product may be new or refurbished of equivalent or better specifications, relative to the 

defective product.  Replacement product need not be of identical design or model.  Any repair or replacement product 

pursuant to this warranty shall be warranted for not less than 90 days from date of such repair, irrespective of any earlier 

expiration of original warranty period.  When HBX provides replacement, the defective product becomes the property of 

HBX Controls. 
Warranty Service, within the applicable warranty period, may be obtained by contacting your nearest HBX Controls office 

via the original Authorized Agent and requesting a Return Material Authorization Number (RMA #).  Proof of purchase in the 

form a dated invoice/receipt must be provided to expedite the issuance of a Factory RMA.
After an RMA number has been issued, the defective product must be packaged securely in the original or other suitable 

shipping package to ensure that it will not be damaged in transit.  The RMA number must be visible on the outside of the 

package and a copy included inside the package.  The package must be mailed or otherwise shipped back to HBX with all 

costs of mailing/shipping/insurance prepaid by the warranty claimant.
Any package/s returned to HBX without an approved and visible RMA number will be rejected and shipped back to 

purchaser at purchaser’s expense.  HBX reserves the right, if deemed necessary, to charge a reasonable levy for costs 

incurred, additional to mailing or shipping costs.

Limitation of Warranties

If the HBX product does not operate as warranted above the purchasers sole remedy shall be, at HBX’s option, repair 

or replacement.  The foregoing warranties and remedies are exclusive and in lieu of all other warranties, expressed or 

implied, either in fact or by operation of law, statutory or otherwise, including warranties of merchantability and fitness for 

a particular purpose/application.  HBX neither assumes nor authorizes any other person to assume for it any other liability in 

connection with the sale, installation maintenance or use of HBX Controls products.
HBX shall not be liable under this warranty; if its testing and examination discloses that the alleged defect in the 

product does not exist or was caused by the purchasers or third persons misuse, neglect, improper installation or testing, 

unauthorized attempts to repair or any other cause beyond the range of intended use, or by accident, fire, lightning or 

other hazard.

Limitation of Liability

In no event will HBX be liable for any damages, including loss of data, loss of profits, costs of cover or other incidental, 

consequential or indirect damages arising out of the installation, maintenance, commissioning, performance, failure or 

interruption of an HBX product, however caused and on any theory of liability.  This limitation will apply even if HBX has been 

advised of the possibility of such damage.

Local Law

This limited warranty statement gives the purchaser specific legal rights.  The purchaser may also have other rights which 

vary from state to state in the United States, from Province to Province in Canada and from Country to Country elsewhere in 

the world.
To the extent this Limited Warranty Statement is inconsistent with local law, this statement shall be deemed modified to be 

consistent with such local law.  Under such local law, certain disclaimers and limitations of this statement may not apply 

to the purchaser.  For example, some states in the United States, as well as some governments outside the United States 

(including Canadian Provinces), may:
Preclude the disclaimers and limitations in this statement from limiting the statutory rights of a consumer (e.g. United 

Kingdom);
Otherwise restrict the ability of a manufacturer to enforce such disclaimers or limitations; or 
Grant the purchaser additional warranty rights which the manufacturer cannot disclaim, or not allow limitations on the 

duration of implied warranties.

Summary of Contents for ECO-0600

Page 1: ...HBX Control Systems Inc Installation Manual ECO 0600 Version 1 0 0 ECO 0600 Geothermal Control...

Page 2: ...0 0 0 Table of Contents TABLE OF CONTENTS Introduction 1 3 Description 1 Safety Symbols Warnings 2 Receipt Inspection 2 Technical Data and Dimensions 3 Wiring Installation 4 25 Wiring 4 Installation...

Page 3: ...applications with separate hot and cold tanks This control can also function as a stand alone system without WiFi capabilities FEATURES App for Android or Apple Smartphone tablet device for remote ac...

Page 4: ...ca gov WARNING a Use copper conductors only if the terminal is acceptable only for connections to copper wire b Use aluminum conductors only or use aluminum or copper clad aluminum condctors only if...

Page 5: ...VAC 1 2hp FLA or LRA 5A Max Pump 120VAC 240VAC 5A Max Other 1x Input 120VAC 10 50 60Hz 250mA Max Combined relay power should not exceed 15A Weight 0 408Kg Dimensions 121mm W x 188mm H x 66mm 4 76in W...

Page 6: ...ev Valve Output Auxiliary Output 2 Auxiliary Output 1 DO NOT CONNECT POWER HERE GR POWER 120 17 N L 16 15 5A 1 Aux 1 9 10 1 2 Aux 2 11 12 2 5A HBX ECO 0600 GEOTHERMAL CONTROL 1 8 7 2 HD 3 10 9 4 CD De...

Page 7: ...e heat pump will light up in respect to their classification REV VALVE When a cooling demand is activated the Rev Valve will light up to indicated it is on PUMPS When a pump is activated by a call you...

Page 8: ...STATUS Sync Code Sync Code of the ECO 0600 Wi Fi Network displays current SSID network connected to Wi Fi Password displays password of current network connected to Wi Fi Strength displays Signal str...

Page 9: ...l be set for the minimum OFF lagtime between heat pump stages Rotate Time Rotate Time The time of rotation between heat pumps This setting is in hours of run time This means that the heat pumps are go...

Page 10: ...you are not using outdoor reset With this option enabled the Tank Temperature setting will be replaced by Min Tank and Max Tank Temperature settings OFF 40 F to 127 F Default OFF Differential Set this...

Page 11: ...you are not using outdoor reset With this option enabled the Tank Temperature setting will be replaced by Min Tank and Max Tank Temperature settings OFF 0 F to 119 F Default OFF Differential Set this...

Page 12: ...is is the differential for the DHW tank Set this parameter to the desired differential for the DHW tank 2 F to 100 F Default 8 F Differential DHW Target Use DHW Tank WWSD CWSD TIME This setting is use...

Page 13: ...or on its own to bring the backup on This setting is used to set a differential on the tank at which you would like the backup to come on This setting will override the backup temperature and backup t...

Page 14: ...2 Start Delay the amount of time if necessary for Pump 1 be delayed to run after the call associated with it has been activated Allowed Values 0 240 Seconds Pump Exercise Time the amount of time if n...

Page 15: ...tize a heating demand over a cooling demand Cooling The control will prioritize a cooling demand over a heating demand Auto The control will automatically set the priority based off how close the outd...

Page 16: ...Scan Pressing this will allow the ECO 0600 to actively scan for all available networks that you can choose from and then you may select the 2 4 GHz network that you wish to connect to Wi Fi SSID Manu...

Page 17: ...manent cool demand This can be used instead of attaching a thermostat OFF ON Default OFF RUN TIMES This setting will allow you to view your heat pump S and or backup boiler run times Reset Run Times S...

Page 18: ...Fri Sat Sun Time Zone Select the time zone for your area STANDARD TIMEZONES DAYLIGHT SAVINGS Atlantic Standard Time AST GMT 4 Eastern Standard Time EST GMT 5 Central Standard Time CST GMT 6 Mountain...

Page 19: ...r Inputs 1 MOD 1 2 1 1 2 4 3 2 3 6 5 3 Mod Staging Output MOD 2 MOD 3 4 STG 4 7 8 4 3 5 6 3 2 3 4 2 1 1 2 1 Staging Output STG 3 STG 2 STG 1 5A 3 Rev Valve 13 14 3 ECO 0600 Input Power DO NOT CONNECT...

Page 20: ...or Inputs 1 MOD 1 2 1 1 2 4 3 2 3 6 5 3 Mod Staging Output MOD 2 MOD 3 4 STG 4 7 8 4 3 5 6 3 2 3 4 2 1 1 2 1 Staging Output STG 3 STG 2 STG 1 5A 3 Rev Valve 13 14 3 ECO 0600 Input Power DO NOT CONNECT...

Page 21: ...2 1 1 2 4 3 2 3 6 5 3 Mod Staging Output MOD 2 MOD 3 4 STG 4 7 8 4 3 5 6 3 2 3 4 2 1 1 2 1 Staging Output STG 3 STG 2 STG 1 5A 3 Rev Valve 13 14 3 ECO 0600 Input Power DO NOT CONNECT HERE DO NOT CONN...

Page 22: ...s 1 MOD 1 2 1 1 2 4 3 2 3 6 5 3 Mod Staging Output MOD 2 MOD 3 4 STG 4 7 8 4 3 5 6 3 2 3 4 2 1 1 2 1 Staging Output STG 3 STG 2 STG 1 5A 3 Rev Valve 13 14 3 ECO 0600 Input Power DO NOT CONNECT HERE DO...

Page 23: ...differential settings Check heat pump lag time Backup boilers not coming on Check wiring Check backup settings Ensure one backup setting is not set to off Backup boiler taking too long to come on Che...

Page 24: ...is not turning on Control is CWSD No cool demand No power Check wiring on pins 15 16 17 Can t connect to Wi Fi Verify SSID and password Must connect to the 2 4 GHz network Ensure port 1314 is open Ch...

Page 25: ...sers sole remedy shall be at HBX s option repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operat...

Page 26: ...H B X E C O 0 6 0 0 G e o t h e r m a l C o n t r o l V e r s i o n 1 0 0 Page 24 NOTES...

Page 27: ...H B X E C O 0 6 0 0 G e o t h e r m a l C o n t r o l V e r s i o n 1 0 0 Page 25 NOTES...

Page 28: ...ems Inc 2021 Toll Free Technical Support 1 855 410 2341 Phone 1 403 720 0029 Fax 1 403 720 0054 Email info hbxcontrols com Web www hbxcontrols com HBX Control Systems Inc 4516 112th Avenue SE Calgary...

Reviews: