Structure and mode of operation
18
A4359-1.0
HBM: public
PW15iA
5
Mechanical installation
5.1
Important precautions during
installation
S
Handle the transducer with care.
S
Welding currents must not be allowed to flow over the
transducer. If there is a risk that this might happen,
you must provide a suitable low-ohm connection to
electrically bypass the transducer. HBM provides the
highly flexible EEK ground cable for this purpose, for
example. It can be screwed on above and below the
transducer.
S
Make sure that the transducer cannot be overloaded.
WARNING
There is a danger of the transducer breaking if it is over
loaded. This can cause danger for the operating person
nel of the system in which the transducer is installed.
Implement appropriate safety measures to avoid over
loads or to protect against the resulting dangers.
Notice
The length of the fastening screws must not exceed the
maximum thread reach of 10mm, as otherwise the trans
ducer could be damaged.