HB-100/140/160Z1
Temperature Control Unit
Operation
98
O8285-EN 2017-12
Select values
Proceed as follows to choose the values to be recorded:
1.
Display the menu page
Settings \ Recording USB
2.
Select the desired value and confirm with the
key.
The active value is indicated with the
symbol.
NOTICE!
You may choose as many values as you like.
File name
For each unit, a separate directory is automatically generated on
the USB data carrier and the recording files are written in it.-
Exa.
HB_Data_00001234
GIF ID
The unit automatically creates file names on the USB data carrier
according to the following examples:
Exa.
HB140Z1_00001234_20100215_165327.csv
Time
Date
GIF ID
Device type
NOTICE!
The GIF-ID can be seen under
Display \ Module
.
Visualize the data recorded
To visualize and prepare the actual data recorded, the VIP
(Visualisation programme
– Recording of actual values) software