HB-100/140/160Z1
Temperature Control Unit
Operation
O8285-EN 2017-12
75
8.6 Switching off
Fig. 42: Main switch
After use, switch the temperature control unit off as follows:
1.
Press the
key.
The temperature control unit cools until the main and return
line temperature is lower than the set safety cut-off
temperature.
Afterwards, a pressure release is carried out.
After this, the temperature control unit switches off. In the
operating mode display, "Ready to operate" is indicated.
2.
Turn the main switch to position "0".
Switch-off without pressure relief
Fig. 43: Pressure relief with unit OFF
In order to switch the temperature control unit off without pressure
relief, make the following settings:
1.
Display the menu page
Setting \ Miscellaneous
.
2.
Set parameter
Pressure relief with unit OFF
to "OFF".
Switching off with mould
evacuation
In order to switch the temperature control unit off with mould
evacuation, make the following settings:
1.
Display the menu page
Settings \ Miscellaneous
.
2.
Set the parameter
Pressure relief with unit OFF
to "Mould
evacuation".