7
Check that the available electrical power supply and the network
frequency correspond to the required operating current, taking into
account the appliance’s specific location and the current needed to
power any other appliance connected to the same circuit.
HPR06M 230 V
+/- 10 % 50 Hz 1 Phase
HPR09M 230 V
+/- 10 % 50 Hz 1 Phase
HPR12M 230 V
+/- 10 % 50 Hz 1 Phase
HPR19M 230 V
+/- 10 % 50 Hz 1 Phase
See the corresponding wiring diagram in the appendix.
The connection box is located on the right side of the unit. Three of the
connections are for the power supply and two are for the filtration pump
control (Servo control, OUT2).
3. INSTALLATION AND CONNECTION (continued)
3.4 Electrical Connection
F
NF C15-100
GB
BS7671:1992
D
DIN VDE 0100-702
EW EVHS-HD 384-7-702
A
ÖVE 8001-4-702
H
MSZ 2364-702/1994/MSZ 10-553 1/1990
E
UNE 20460-7-702 1993,
RECBT ITC-BT-31 2002
M
MSA HD 384-7-702.S2
IRL Wiring Rules + IS HD 384-7-702
PL
PN-IEC 60364-7-702:1999
I
CEI 64-8/7
CZ
CSN 33 2000 7-702
LUX 384-7.702 S2
SK
STN 33 2000-7-702
NL
NEN 1010-7-702
SLO SIST HD 384-7-702.S2
P
RSIUEE
TR
TS IEC 60364-7-702
The electrical installation and wiring of this equipment must comply
with local installation standards.
Dry contact 7A max
potential free.
Priority heating function
L N
1 2
= =
= =
Power supply
230V
/ 50Hz
OUT2
Summary of Contents for HeatRelax HPR06M
Page 2: ......
Page 23: ...19 Page laissée blanche intentionnellement ...
Page 34: ......
Page 35: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ISHPR HeatRelax HeatRelax ...
Page 55: ...19 Page left intentionally blank ...
Page 66: ......
Page 87: ...19 Página en blanco intencionalmente ...
Page 98: ......
Page 119: ...19 Página deixada em branco intencionalmente ...
Page 130: ......
Page 131: ...HEIZPUMPENANLAGE FÜR EIN SCHWIMMBECKEN Einbau Anleitungshandbuch ISHPR HeatRelax HeatRelax ...
Page 151: ...19 Seite bewusst leer gelassen ...
Page 162: ......
Page 163: ...ZWEMBAD WARMTEPOMP Installatie en bedieningshandleiding ISHPR HeatRelax HeatRelax ...
Page 183: ...19 Opzettelijk leeg gelaten pagina ...
Page 194: ......
Page 215: ...19 Pagina lasciata intenzionalmente bianca ...
Page 226: ......
Page 227: ...Varmepumpe til svømmebasseng Installerings og brukerveiledning ISHPR HeatRelax HeatRelax ...
Page 247: ...19 Denne siden er blank med hensikt ...
Page 258: ......
Page 259: ...LÄMPÖPUMPPU UIMA ALTAALLE Asennus ja ohjekirja ISHPR HeatRelax HeatRelax ...
Page 279: ...19 Tarkoituksellisesti tyhjä ...
Page 290: ......
Page 291: ...VÄRMEPUMP FÖR BASSÄNG Bruksanvisning och installationsmanual ISHPR HeatRelax HeatRelax ...
Page 311: ...19 Avsiktligt lämnats tom ...
Page 322: ......
Page 343: ...19 Намеренно оставлено пустым ...
Page 354: ......
Page 355: ......