USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 23 of 76
HCP3000 SERIES Variable Speed Pump
ISHCP3000VSPC Rev -B
6.9 Diagnostic Menu
Buttons
Screen Used
Comments
1.
< >
Use > to enter Diagnostic Menu
and toggle between displays
2.
Displays motor drive serial number.
3.
Displays display board and drive board
firmware
revisions.
4.
Displays pump SKU.
5.
Real-time display of line voltage status connected to
drive (within range, too high, or too low).
6.
Real-time display of motor input current.
7.
Real-time display of pump power usage.
8.
Display showing temperature of motor drive module
and
heatsink.
9.
Display showing Comm Bus communication status
between the motor drive and Hayward control, and
pump address for communication.
10.
+ -
Use + to view event log
Note:
For troubleshooting purposes, the Event Log will record the last twenty error/trip conditions and/or status
messages, as well as the amount of time that has elapsed since the condition occurred. See section 11.2 for more
detail.
Diagnostic Menu
Press > to enter
Serial Number
03100002
Disp Rev: R3.1.0C
Drive Rev: 1.20
Input Voltage
Within Range
Motor Current
1.1A (0-13.0A)
Power Usage
225W (0-2650W)
Drive: 38ºC
Heatsink: 32ºC
Comm Bus: Online
HUA: 10-00-00-00-55
Event log
Press + to view
Product Version
SP3400VSP