13: Condition
Pump Tripping Breaker
Check power being supplied from the breaker. If
200-250VAC go to 13D, if no/low check
panel/breaker.
Check breaker type
Check breaker type and all connections. If
breaker health and connections are confirmed
and problem still exists, replace drive.
Measure power
Step 13C
Step 13D
Page 26
Note: In cases where a GFCI breaker experiences nuisance trips (despite confirming the pump and circuit are
in good health), the Siemens QF220 has proven effective.