13: Condition
Pump Tripping Breaker
Verify the incoming power circuit. Make sure
wires are clean and are not shorting to the cover
plate. Verify and go to 13B.
Disconnect power wires
Disconnect power from mains and engage
breaker. If breaker does not trip go to 13C, if
breaker trips, wiring has short OR bad breaker.
Inspect incoming power
Step 13A
Step 13B
When the breaker that supplies the pump with power continually trips, the
problem is either a short to ground, the drive, or the breaker.
Page 25
Note: GFCI breakers are more susceptible to nuisance tripping. Make sure any breakers being used comply
with all product specifications (outlined in the installation manuals).