USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
44
Name -
Rename the Filter Pump to whatever name you desire.
Type -
Change the type of Filter Pump that is configured (Single Speed,
2-Speed, or VSP)
HUA -
Match the HUA (Hayward Unique Address) to the configured Filter
Pump. This option only appears if the Filter Pump is configured as a Vari-
able Speed Pump.
Speed -
Change the Minimum and Maximum Allowed Speeds of the Filter
Pump as well as the Low, Medium and High speed settings. This option
only appears if the FIlter Pump is configured as a Variable Speed Pump.
Relay -
Select the relay(s) that the Filter Pump is wired to. This option
only appears if the Filter Pump is configured as a single speed or 2-Speed
pump.
Off for Valve Change -
Select whether you want the Filter Pump to shut off
while valves are turning.
Flow Monitoring -
Select whether you want flow to be monitored in this
Body of Water.
Priming -
Select whether you want the Filter Pump to prime. This option
only appears if the FIlter Pump is configured as a 2-Speed or Variable
Speed Pump.
Freeze Protect -
Select whether you want the Filter Pump to turn on for
Freeze Protection. Also set the Freeze Protect air temperature threshold
from this menu. Freeze protect operation can be overridden for a 60 min-
ute period. (See Operation manual for more information).
If Heaters is selected:
Add a Heater -
Pressing “Add a Heater” from this screen will take you through
the full configuration for adding a new heater. These steps are described in the
Configuration Wizard portion of this manual.
General Heater Options -
Pressing this button will take you to a screen will the
following general options for heater operation:
Extend -
Select whether you want Heater Extend enabled for this Body of
Water.
Cooldown -
Select whether you want Heater Cooldown enabled for this
Body of Water.
Max Temperature -
Select the Maximum Allowed Heater Setpoint Tem-
perature for this Body of Water.