background image

Aqua Rite Pro

Side mounting AQL-CHEM to the Aqua Rite Pro: 

Side mounting the AQL-CHEM will

require drilling 3 mounting holes through the Aqua Rite Pro enclosure. Dimples have

been pre-punched on the enclosure at the drilling location (template not needed).

After drilling, be sure to remove any burrs and brush away any metal shavings.

Route Probe Cell cable through the access hole at the bottom of the mounting

bracket BEFORE screwing the bracket in place.  For easiest installation, fasten the

nylon lock nut loosely, then slip the bracket keyhole slots over the bolt head and

tighten.  After installation, coil excess cable in the Aqua Rite Pro enclosure. Refer to

the diagram below.

Pro Logic

Side mounting AQL-CHEM to Pro Logic: 

Side mounting the AQL-CHEM will require

drilling 3 mounting holes through the Pro Logic enclosure. A drill template is included

with the AQL-CHEM to assist with the positioning of the holes.  After drilling, be sure

to remove any burrs and brush away any metal shavings.  Route Probe Cell cable

through the access hole at the bottom of the mounting bracket BEFORE screwing the

bracket in place.  For easiest installation, fasten the nylon lock nut loosely, then slip

the bracket keyhole slots over the bolt head and tighten.  After installation, coil

excess cable in the Pro Logic enclosure. Refer to the diagram below.

3

Route probe cell cable
through access hole 
BEFORE mounting.

metal washer

rubber
washer

Aqua Rite Pro
enclosure wall

AQL-CHEM
bracket wall

Zip Tie and store extra
cable length here

Side Mounting

AQL-CHEM to Aqua Rite Pro

Route probe cell cable
through access hole 
BEFORE mounting.

metal washer

rubber
washer

Pro Logic
enclosure wall

AQL-CHEM
bracket wall

Side Mounting

AQL-CHEM to Pro Logic

Zip Tie and store extra
cable length here

16

Winterizing

The AQL-CHEM probes must be protected from freezing conditions. If the pool is

winterized, plan to remove and store the probes (as described above) as part of the

normal pool winterizing process.  The Probe Cell and related plumbing must be drained

as well.  BNC connectors should be capped with the original protective covers. A

winterizing kit with probe caps, BNC covers, and other necessary winterizing acces-

sories is available to replace any missing items. Contact your local Hayward dealer for

more information.

Summary of Contents for AQL-CHEM

Page 1: ...ayward pool com Total Pool Chemistry Aqua Rite Pro Pro Logic Installation and Operation Manual for AQL CHEM North Kingstown RI 02852 USA Questions Refer to www goldlinecontrols com for latest manual revisions additional information and helpful service and for T M T M T M Work less play more ...

Page 2: ...a Rite Aqua Rite Pro Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship under normal use and service for a period of three 3 years Hayward Goldline also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship under normal use and service for a period of one 1 year These warranties are applicable from the initial d...

Page 3: ...Logic for drill template Mounting hardware if surface mounting not side mounting Flex tubing cutter Water tight strain relief for dispense pigtail Flathead screwdriver and mallet to remove knock out and install strain relief 120VAC Ground Fault Circuit Breaker GFCB for powering 120VAC dispense pigtail or 240VAC GFCB for powering 240VAC dispense pigtail Extra wire wire strippers and wire nuts could...

Page 4: ...he mounting bracket BEFORE screwing the bracket in place For easiest installation fasten the nylon lock nut loosely then slip the bracket keyhole slots over the bolt head and tighten After installation coil excess cable in the Pro Logic enclosure Refer to the diagram below 3 Route probe cell cable through access hole BEFORE mounting metal washer rubber washer Aqua Rite Pro enclosure wall AQL CHEM ...

Page 5: ... residual in parts per million ppm periodically adjust the ORP level Probe Maintenance The probes must be clean and free from oil chemical deposits and contamination to function properly After saturation in pool or spa water the probes may need to be cleaned on a weekly or monthly basis depending on bather load and other pool specific characteristics Slow response increased need to calibrate pH an...

Page 6: ...Both systems are effective at reducing pH but CO2 is much safer to handle and store The HaywardAQL CHEM2 240 are CO2 dispensing systems that eliminate the need to handle acid and are economical and efficient meth ods for effective pH control When the CO2 gas is injected into water it dissolves and becomes carbonic acid a weak acid that is very effective at lowering pH but becomes self limiting if ...

Page 7: ...y turns on and applies power to the CO2 feed solenoid or acid dispense pump Once this is verified set pH Reduction CTRL back to AUTO As a last check for proper configuration push the corresponding output button for the pH Dispensing device The device SHOULD NOT TURN ON If it does go back through the configuration to determine the problem Operation Before operating the AQL CHEM test and adjust the ...

Page 8: ...tallation the pH probe must be calibrated using the pH Calibration Wizard Periodically a pool water test should be compared to the pH level reported by the Aqua Rite Pro or Pro Logic If there is a discrepancy between the two values the pH Calibration Wizard should be redone Run the pool pump for a minimum of 20 minutes before starting the pH Calibration Wizard The procedure to perform the Wizard i...

Page 9: ...n the pool and automatically adjusts chlorine output to maintain a desired level Timed The chlorine output is based on the manual setting only ORP level is not used to control the chlorinator output MaintainpHLevel The Wizard prompts you to enter the desired pH level 7 5 default TheAqua Rite Pro or Pro Logic will dispense CO2 or other pH reducer when necessary to maintain this level The adjustable...

Page 10: ...e following pages To enter the Chemistry Config Wizard follow the steps below Aqua Rite Pro 1 Press the Settings button 2 Press repeatedly until Chemistry Config Wizard is displayed 4 Push to start Wizard 5 Advance through the Wizard using and buttons Use and buttons to answer questions when prompted 6 Continue until finished Pro Logic If theAQL CLchlorination kit will be used be sure that it is e...