background image

9

10

Pro Logic operating with software version 4.00 or later

Pro Logics operating with software version 4.00 or later have built-in support for the

AQL-CHEM2 or other 120VAC pH dispensing devices. A screw terminal block mounted

inside of the Pro Logic enclosure offers a dedicated connection to the 120VAC pigtail

or device.  The diagram below shows typical wiring information for these Pro Logic

units.

Pigtail

to AQL-CHEM2

120VAC

pH dispense Pigtail

 

(included with AQL-CHEM)

use watertight

strain relief here

factory wiring

N

L1

Configuring the Aqua Rite Pro or Pro Logic

After the AQL-CHEM is mounted, plumbed and wired, the Aqua Rite Pro or Pro Logic

must be configured using the Chemistry Config. Wizard and pH Calibration Wizard.

These wizards are found in the Settings Menu of the Aqua Rite Pro.  For the Pro Logic,

the Chemistry Config. Wizard is found in the Configuration Menu and the pH Calibra-

tion Wizard is found in the Maintenance Menu.

If a pH dispensing device is used, the relay that is used to control the device must be

configured.  Refer to page 12 for detailed information.

Chemistry Config Wizard

The Chemistry Config Wizard will prompt the user for information and automatically

configure the Aqua Rite Pro or Pro Logic to use the AQL-CHEM sensing kit. The

procedure to perform the Wizard is shown below.  Detailed information about specific

screens relating to the configuration can be found on the following pages.  To enter

the Chemistry Config Wizard follow the steps below:

Aqua Rite Pro

1.

Press the "Settings" button.

2.

Press ">" repeatedly until "Chemistry Config. Wizard" is displayed.

4.

Push "+" to start Wizard.

5.

Advance through the Wizard using "<" and ">" buttons.  Use "+" and "-"

buttons to answer questions when prompted.

6.

Continue until finished.

Pro Logic

If the AQL-CL chlorination kit will be used, be sure that it is enabled BEFORE entering

the Chemistry Config Wizard.

1.

Press "Menu" until Configuration Menu is displayed.

2.

Hold both "<" and ">" for three seconds.

3.

Press ">" repeatedly until "Chemistry Config. Wizard" is displayed.

4.

Push "+" to start Wizard.

5.

Advance through the Wizard using "<" and ">" buttons.  Use "+" and "-"

buttons to answer questions when prompted.

6.

Continue until finished.

Sensing System

Select Enable to configure the AQL-CHEM.

pH Reduction Control

Select the desired option related to pH control.

Disabled

pH control is turned off. Select this mode if no pH dispenser will be

connected to the Aqua Rite Pro or Pro Logic.

Auto Sensing

Use this mode when an AQL-CHEM2(-240) kit or other type of auto-

matic pH reducer will be used. The Aqua Rite Pro or Pro Logic will

dispense pH reducer (CO

2

 or acid) when necessary to prevent the

pH level from rising.

Forced On

pH reducer is added for 15 minutes regardless of pH level and then

automatically goes to Auto Sensing mode.  This mode is helpful

when setting up and testing the AQL-CHEM2(-240) or other auto-

matic dispenser.

to Line

on GFCB

to Neutral
on GFCB

Pigtail

to AQL-CHEM2

120 VAC Load

120 VAC

GFCB 

pH dispense Pigtail

 

(included with AQL-CHEM)

use watertight

strain relief here

120VAC

Summary of Contents for AQL-CHEM

Page 1: ...ayward pool com Total Pool Chemistry Aqua Rite Pro Pro Logic Installation and Operation Manual for AQL CHEM North Kingstown RI 02852 USA Questions Refer to www goldlinecontrols com for latest manual revisions additional information and helpful service and for T M T M T M Work less play more ...

Page 2: ...a Rite Aqua Rite Pro Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship under normal use and service for a period of three 3 years Hayward Goldline also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship under normal use and service for a period of one 1 year These warranties are applicable from the initial d...

Page 3: ...Logic for drill template Mounting hardware if surface mounting not side mounting Flex tubing cutter Water tight strain relief for dispense pigtail Flathead screwdriver and mallet to remove knock out and install strain relief 120VAC Ground Fault Circuit Breaker GFCB for powering 120VAC dispense pigtail or 240VAC GFCB for powering 240VAC dispense pigtail Extra wire wire strippers and wire nuts could...

Page 4: ...he mounting bracket BEFORE screwing the bracket in place For easiest installation fasten the nylon lock nut loosely then slip the bracket keyhole slots over the bolt head and tighten After installation coil excess cable in the Pro Logic enclosure Refer to the diagram below 3 Route probe cell cable through access hole BEFORE mounting metal washer rubber washer Aqua Rite Pro enclosure wall AQL CHEM ...

Page 5: ... residual in parts per million ppm periodically adjust the ORP level Probe Maintenance The probes must be clean and free from oil chemical deposits and contamination to function properly After saturation in pool or spa water the probes may need to be cleaned on a weekly or monthly basis depending on bather load and other pool specific characteristics Slow response increased need to calibrate pH an...

Page 6: ...Both systems are effective at reducing pH but CO2 is much safer to handle and store The HaywardAQL CHEM2 240 are CO2 dispensing systems that eliminate the need to handle acid and are economical and efficient meth ods for effective pH control When the CO2 gas is injected into water it dissolves and becomes carbonic acid a weak acid that is very effective at lowering pH but becomes self limiting if ...

Page 7: ...y turns on and applies power to the CO2 feed solenoid or acid dispense pump Once this is verified set pH Reduction CTRL back to AUTO As a last check for proper configuration push the corresponding output button for the pH Dispensing device The device SHOULD NOT TURN ON If it does go back through the configuration to determine the problem Operation Before operating the AQL CHEM test and adjust the ...

Page 8: ...tallation the pH probe must be calibrated using the pH Calibration Wizard Periodically a pool water test should be compared to the pH level reported by the Aqua Rite Pro or Pro Logic If there is a discrepancy between the two values the pH Calibration Wizard should be redone Run the pool pump for a minimum of 20 minutes before starting the pH Calibration Wizard The procedure to perform the Wizard i...

Page 9: ...n the pool and automatically adjusts chlorine output to maintain a desired level Timed The chlorine output is based on the manual setting only ORP level is not used to control the chlorinator output MaintainpHLevel The Wizard prompts you to enter the desired pH level 7 5 default TheAqua Rite Pro or Pro Logic will dispense CO2 or other pH reducer when necessary to maintain this level The adjustable...

Page 10: ...e following pages To enter the Chemistry Config Wizard follow the steps below Aqua Rite Pro 1 Press the Settings button 2 Press repeatedly until Chemistry Config Wizard is displayed 4 Push to start Wizard 5 Advance through the Wizard using and buttons Use and buttons to answer questions when prompted 6 Continue until finished Pro Logic If theAQL CLchlorination kit will be used be sure that it is e...