background image

Description

The AQL-CHEM is an ORP and pH sensing kit that is offered as an accessory for all

Hayward Aqua Rite Pro chlorine generators and Pro Logic pool controls.  With the

AQL-CHEM, the Aqua Rite Pro or Pro Logic can provide a fully integrated chemistry

solution for your pool.  The AQL-CHEM continuously tests the pool's sanitation and

pH levels allowing the Aqua Rite Pro or Pro Logic to automatically generate the

correct amount of chlorine and dispense the proper amount of pH reducer. Together,

they provide an automated system controlling both sanitization and pH balance.

The AQL-CHEM comes with two pigtails (120VAC and 240VAC) for connection to a

pH reducing device like a peristaltic pump or solenoid valve (not included) that re-

quires a line cord receptacle.  For easy integration, Hayward offers the AQL-CHEM2

(120VAC) and AQL-CHEM2-240 (240VAC) CO

dispense kit that plugs into the pigtail

and will reduce the pool's pH level by injecting CO

into the pool water.

What's Included

The AQL-CHEM comes with everything needed to allow the Aqua Rite Pro or Pro

Logic to sense ORP and pH levels.  The following is a description of the included

components:

Professional Grade ORP probe- 

Samples water from the pool filtration system and

sends signals to the Aqua Rite Pro or Pro Logic indicating the oxidation-reduction

potential (redox) of the pool water. ORP is an actual measurement of  sanitizer activity

and bacteriological water quality rather than an expression of chemical residual levels.

ORP is not fooled by the effects of pH, TDS (total dissolved solids) and other factors

giving a more accurate measurement of the effectiveness of chlorine and water qual-

ity.

Professional Grade pH probe- 

Samples water from the pool filtration system and

sends signals to the Aqua Rite Pro or Pro Logic indicating the acidity of the water.

When used with a Hayward AQL-CHEM2 or other pH dispensing device, the Aqua

Rite Pro or Pro Logic can keep the pool water's pH level balanced.

Probe Cell: 

 The Probe Cell is used to house the probes and provide a location for

water collection and testing.  Two hoses are provided to connect the Probe Cell to the

supply and return sides of the pool filtration system. The Probe Cell can be mounted

directly to the Aqua Rite Pro/Pro Logic or remote mounted in the vicinity of the

control (restricted by the length of the probe wiring).

Additional Pro Logic Relay:  

An additional relay is provided for Pro Logic PL-PS-4

and PL-P-4 models operating with software version less than 4.00.  Refer to the Pro

Logic manual for instruction on how to determine  your software revision.  The

additional relay allows the user to add the AQL-CHEM2 or other pH reducing device

to these models.  Install this relay only if you have one of these models and intend to

add pH control.

pH Dispense Pigtails:

 The pH Dispense pigtails provide a plug-in receptacle for the

AQL-CHEM2, AQL-CHEM2-240 or other pH related dispensing device (peristaltic

pumps, solenoid valves, etc.) that will be controlled by the Aqua Rite Pro or Pro Logic.

Various Hardware: 

The AQL-CHEM includes the necessary tubing, tubing connec-

tors and mounting hardware to complete the installation.

1

18

LIMITED WARRANTY (effective 04/01/09) 

Hayward/Goldline warrants its Pro Logic

and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro,

Aqua Plus and SwimPure chlorination products to be free of defects in materials and

workmanship, under normal use and service, for a period of three (3) years.  Hayward/

Goldline also warrants its Aqua Trol chlorination products to be free of defects in

materials and workmanship, under normal use and service for a period of one (1) year.

These warranties are applicable from the initial date of installation on private residen-

tial swimming pools in the US and Canada.

Hayward/Goldline warrants all the above-identified pool automation and chlorination

products installed on commercial swimming pools and on swimming pools outside of

the US and Canada for a period of one (1) year.  Likewise,   Hayward/Goldline warrants

all accessories and replacement parts for the above-identified pool automation and

chlorination products for a period of one (1) year.  Each of these warranties is not

transferable and applies only to the original owner.

Proof of purchase is required for warranty service.  If written proof of purchase is not

provided, the manufacturing date code will be the sole determinant of the date of

installation of the product.  To obtain warranty service or repair, please contact the

place of purchase or the nearest Hayward/Goldline authorized warranty service cen-

ter.  For more information on authorized service centers please contact the Hayward/

Goldline Technical Service Support Center (61 Whitecap Road, North Kingstown RI,

02852) or visit the Goldline web site at www.goldlinecontrols.com or the Hayward

website at www.haywardnet.com.

WARRANTY EXCLUSIONS

:

1. Material supplied or workmanship performed by others in process of installation.

2. Damage resulting from improper installation including installation on pools larger

than the product rating.

3. Problems resulting from failure to install, operate or maintain the product(s) in

accordance with the recommendations contained in the owners manual(s).

4. Problems resulting from failure to maintain pool water chemistry in accordance with

the recommendations in the owners manual(s).

5. Problems resulting from tampering, accident, abuse, negligence, unauthorized re-

pairs or alternations, fire, flood, lightning, freezing, external water, degradation of

natural stone used in or immediately adjacent to a pool or spa, war or acts of God.

DISCLAIMER.  THE EXPRESS LIMITED WARRANTIES ABOVE CONSTITUTE

THE ENTIRE WARRANTIES WITH RESPECT TO THE ABOVE-IDENTIFIED HAY-

WARD/GOLDLINE POOL AUTOMATION AND CHLORINATION PRODUCTS

AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, IN-

CLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PAR-

TICULAR PURPOSE. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL

RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS OF EQUIPMENT, LOST

PROFITS OR REVENUE, COSTS OF RENTING REPLACEMENTS, AND OTHER

ADDITIONAL EXPENSES, EVEN IF THE SELLER HAD BEEN ADVISED OF THE

POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EX-

CLUSION OF LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,

SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.

NO WHOLESALER, AGENT, DEALER, CONTRACTOR OR OTHER PERSON IS

AUTHORIZED TO PROVIDE, SUPPLEMENT OR MODIFY ANY WARRANTY ON

BEHALF OF HAYWARD/GOLDLINE.

THESE WARRANTIES ARE VOID IF THE PRODUCT HAS BEEN ALTERED IN

ANY WAY AFTER LEAVING THE FACTORY. FOR THE ABOVE-IDENTIFIED

CHLORINATION PRODUCTS, THESE WARRANTIES ALSO ARE VOID IF, DUR-

ING THE WARRANTY PERIOD, YOU USE A REPLACEMENT CHLORINATOR

CELL OTHER THAN AN UNMODIFIED, NEW HAYWARD/GOLDLINE CHLORI-

NATOR CELL PURCHASED FROM HAYWARD/GOLDLINE. IF A WARRANTY

BECOMES VOID, YOU STILL MAY PURCHASE SERVICE AND/OR TELEPHONE

TECHNICAL SUPPORT AT THE THEN CURRENT TIME AND MATERIAL RATES.

Summary of Contents for AQL-CHEM

Page 1: ...ayward pool com Total Pool Chemistry Aqua Rite Pro Pro Logic Installation and Operation Manual for AQL CHEM North Kingstown RI 02852 USA Questions Refer to www goldlinecontrols com for latest manual revisions additional information and helpful service and for T M T M T M Work less play more ...

Page 2: ...a Rite Aqua Rite Pro Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship under normal use and service for a period of three 3 years Hayward Goldline also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship under normal use and service for a period of one 1 year These warranties are applicable from the initial d...

Page 3: ...Logic for drill template Mounting hardware if surface mounting not side mounting Flex tubing cutter Water tight strain relief for dispense pigtail Flathead screwdriver and mallet to remove knock out and install strain relief 120VAC Ground Fault Circuit Breaker GFCB for powering 120VAC dispense pigtail or 240VAC GFCB for powering 240VAC dispense pigtail Extra wire wire strippers and wire nuts could...

Page 4: ...he mounting bracket BEFORE screwing the bracket in place For easiest installation fasten the nylon lock nut loosely then slip the bracket keyhole slots over the bolt head and tighten After installation coil excess cable in the Pro Logic enclosure Refer to the diagram below 3 Route probe cell cable through access hole BEFORE mounting metal washer rubber washer Aqua Rite Pro enclosure wall AQL CHEM ...

Page 5: ... residual in parts per million ppm periodically adjust the ORP level Probe Maintenance The probes must be clean and free from oil chemical deposits and contamination to function properly After saturation in pool or spa water the probes may need to be cleaned on a weekly or monthly basis depending on bather load and other pool specific characteristics Slow response increased need to calibrate pH an...

Page 6: ...Both systems are effective at reducing pH but CO2 is much safer to handle and store The HaywardAQL CHEM2 240 are CO2 dispensing systems that eliminate the need to handle acid and are economical and efficient meth ods for effective pH control When the CO2 gas is injected into water it dissolves and becomes carbonic acid a weak acid that is very effective at lowering pH but becomes self limiting if ...

Page 7: ...y turns on and applies power to the CO2 feed solenoid or acid dispense pump Once this is verified set pH Reduction CTRL back to AUTO As a last check for proper configuration push the corresponding output button for the pH Dispensing device The device SHOULD NOT TURN ON If it does go back through the configuration to determine the problem Operation Before operating the AQL CHEM test and adjust the ...

Page 8: ...tallation the pH probe must be calibrated using the pH Calibration Wizard Periodically a pool water test should be compared to the pH level reported by the Aqua Rite Pro or Pro Logic If there is a discrepancy between the two values the pH Calibration Wizard should be redone Run the pool pump for a minimum of 20 minutes before starting the pH Calibration Wizard The procedure to perform the Wizard i...

Page 9: ...n the pool and automatically adjusts chlorine output to maintain a desired level Timed The chlorine output is based on the manual setting only ORP level is not used to control the chlorinator output MaintainpHLevel The Wizard prompts you to enter the desired pH level 7 5 default TheAqua Rite Pro or Pro Logic will dispense CO2 or other pH reducer when necessary to maintain this level The adjustable...

Page 10: ...e following pages To enter the Chemistry Config Wizard follow the steps below Aqua Rite Pro 1 Press the Settings button 2 Press repeatedly until Chemistry Config Wizard is displayed 4 Push to start Wizard 5 Advance through the Wizard using and buttons Use and buttons to answer questions when prompted 6 Continue until finished Pro Logic If theAQL CLchlorination kit will be used be sure that it is e...

Reviews: