Remote surface mounting the AQL-CHEM: 

The Probe Cell can be mounted up to 15'

away from the Aqua Rite Pro or the Pro Logic (limited by length of cable). Use the

four mounting holes on the back of the bracket when surfacing mounting. Common

wood screws can be used for most applications.

Plumbing the Probe Cell to the pool plumbing

The Probe Cell requires connection to the pool plumbing using the supplied flex

tubing.  Two ports on the Probe Cell, influent and effluent, are connected to the

supply and return sides of the pool plumbing.  Refer to diagram below as well as the

following steps:

Use remote

mounting holes
when surface mounting.

Normal Operation

During normal operation, the AQL-CHEM will sense ORP and pH requiring no user

input. The current ORP and pH levels will periodically be shown on the display.

Pushing the "<" or ">" buttons will advance you to this display quickly.  For the Pro

Logic, this information can also be found within the Diagnostic Menu.

The desired ORP and pH levels can be changed by restarting the Chemistry Config.

Wizard.

Maintenance

Water Chemistry

Always test water chemistry with a quality manual test kit.  The AQL-CHEM provides

instrument grade accuracy which exceeds that of most liquid-standard water testing

kits. Therefore, it may be preferable to calibrate pH using commercially available

reference solutions. Calibrate pH periodically using the pH Calibration Wizard as

described earlier in this manual.  It's important to note that changes in pH, cyanuric

acid concentration, total dissolved solids, and use of additional or alternative sanitizers

will all affect the primary sanitizer residual level relative to ORP. Maintain total alkalin-

ity on  regular basis to ensure pH stability. To maintain a consistent sanitizer residual

in parts per million (ppm), periodically adjust the ORP level.

Probe Maintenance

The probes must be clean and free from oil, chemical deposits and contamination to

function properly. After saturation in pool or spa water, the probes may need to be

cleaned on a weekly or monthly basis depending on bather load and other pool

specific characteristics.  Slow response, increased need to calibrate pH, and inconsis-

tent readings are indications that the probes are in need of cleaning.

To clean the ORP and pH probes, run the Clean Probe Wizard within the Settings

Menu on the Aqua Rite Pro or the Maintenance Menu on the Pro Logic. This Wizard

will walk the user through the probe cleaning process. Answer the questions when

prompted, and follow the instructions for proper cleaning.

To clean the probes without running the Wizard, turn off input power to the Aqua Rite

Pro or Pro Logic. Disconnect the probe connectors from the communication box,

unscrew the probe and carefully remove them from the Probe Cell.  Clean the reference

junction (the white ring at the bottom of the probe body) with a soft toothbrush and

regular tooth paste. A household liquid dishwashing detergent may also be used to

remove any oil.  Rinse with fresh water, replace teflon tape on threads and reinstall

probes.  If properly cleaned probes continue to provide unstable readings or require

excessive calibration, the probes should be replaced.

Probe Storage

Exposure to atmospheric conditions will cause the probe tips to dry out. Store the

probes with the included plastic probe storage caps if removed from the Probe Cell for

more than one hour. If the storage caps have been misplaced, store the probes indi-

vidually in small glass or plastic containers with clean water covering the probe tips.

Store probes in a location that will not be subjected to freezing temperatures.

15

FROM

POOL

FROM

SPA

RETURN
TO POOL

RETURN
TO SPA

POOL

Influent

Port

Effluent

Port

Sample

Stream

Port

Summary of Contents for AQL-CHEM

Page 1: ...ayward pool com Total Pool Chemistry Aqua Rite Pro Pro Logic Installation and Operation Manual for AQL CHEM North Kingstown RI 02852 USA Questions Refer to www goldlinecontrols com for latest manual revisions additional information and helpful service and for T M T M T M Work less play more ...

Page 2: ...a Rite Aqua Rite Pro Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship under normal use and service for a period of three 3 years Hayward Goldline also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship under normal use and service for a period of one 1 year These warranties are applicable from the initial d...

Page 3: ...Logic for drill template Mounting hardware if surface mounting not side mounting Flex tubing cutter Water tight strain relief for dispense pigtail Flathead screwdriver and mallet to remove knock out and install strain relief 120VAC Ground Fault Circuit Breaker GFCB for powering 120VAC dispense pigtail or 240VAC GFCB for powering 240VAC dispense pigtail Extra wire wire strippers and wire nuts could...

Page 4: ...he mounting bracket BEFORE screwing the bracket in place For easiest installation fasten the nylon lock nut loosely then slip the bracket keyhole slots over the bolt head and tighten After installation coil excess cable in the Pro Logic enclosure Refer to the diagram below 3 Route probe cell cable through access hole BEFORE mounting metal washer rubber washer Aqua Rite Pro enclosure wall AQL CHEM ...

Page 5: ... residual in parts per million ppm periodically adjust the ORP level Probe Maintenance The probes must be clean and free from oil chemical deposits and contamination to function properly After saturation in pool or spa water the probes may need to be cleaned on a weekly or monthly basis depending on bather load and other pool specific characteristics Slow response increased need to calibrate pH an...

Page 6: ...Both systems are effective at reducing pH but CO2 is much safer to handle and store The HaywardAQL CHEM2 240 are CO2 dispensing systems that eliminate the need to handle acid and are economical and efficient meth ods for effective pH control When the CO2 gas is injected into water it dissolves and becomes carbonic acid a weak acid that is very effective at lowering pH but becomes self limiting if ...

Page 7: ...y turns on and applies power to the CO2 feed solenoid or acid dispense pump Once this is verified set pH Reduction CTRL back to AUTO As a last check for proper configuration push the corresponding output button for the pH Dispensing device The device SHOULD NOT TURN ON If it does go back through the configuration to determine the problem Operation Before operating the AQL CHEM test and adjust the ...

Page 8: ...tallation the pH probe must be calibrated using the pH Calibration Wizard Periodically a pool water test should be compared to the pH level reported by the Aqua Rite Pro or Pro Logic If there is a discrepancy between the two values the pH Calibration Wizard should be redone Run the pool pump for a minimum of 20 minutes before starting the pH Calibration Wizard The procedure to perform the Wizard i...

Page 9: ...n the pool and automatically adjusts chlorine output to maintain a desired level Timed The chlorine output is based on the manual setting only ORP level is not used to control the chlorinator output MaintainpHLevel The Wizard prompts you to enter the desired pH level 7 5 default TheAqua Rite Pro or Pro Logic will dispense CO2 or other pH reducer when necessary to maintain this level The adjustable...

Page 10: ...e following pages To enter the Chemistry Config Wizard follow the steps below Aqua Rite Pro 1 Press the Settings button 2 Press repeatedly until Chemistry Config Wizard is displayed 4 Push to start Wizard 5 Advance through the Wizard using and buttons Use and buttons to answer questions when prompted 6 Continue until finished Pro Logic If theAQL CLchlorination kit will be used be sure that it is e...

Reviews: