HAWE Hydraulik IEP 014-CP Assembly Instructions Manual Download Page 30

Fault

Possible cause

Test

Remedy

Incorrect assignment

of the signal module

Missing terminating resistor

No CAN communica-

tion to the battery pack

Defective CAN topology

in the higher-level system

Check for correct assignment

and correct cabling

see "Plug assignment", page 37

Sensor error codes

Error code

[CAN ID]

dec [hex]

Name of error

Trigger

Dependency

Description

CAN bus

Smart phone (app)

0 [0x0]

ERROR_OVER-

VOLTAGE

Over-voltage

V

moduleMax

 > OV

threshold

Clear: No Trigger (Ignition
+ Override)

Board Param
Outdated Error

Pack or cell voltage too high. Disconnect
any system causing the problem. Ambient
temperature between 5 and 25°C is
advisable. Wait until the battery has
dropped in voltage and connect to a load
in order to discharge the battery.

1 [0x01]

ERROR_UN-

DERVOLTAGE

Under-voltage

V

moduleMin 

< UV

threshold

Clear: No Trigger

Board Param
Outdated Error

Pack or cell voltage too low. Disconnect
any system causing the problem. Ambient
temperature between 20 and 30°C is
advisable. Wait until the battery has
recovered in voltage and connect to a
charger in order to charge the battery.

2 [0x02]

ERROR_OVER_TEM-

PERATURE

Over-Temperature T

ExternalMax 

> Ot

threshold

Clear: No Trigger. Ignition

Board Param
Outdated Error

One of the temperature sensors has
exceeded the maximum temperature.
Disconnect any system causing the
problem. Create an ambient tempera-
ture between 0 and 20°C. Observe if the
battery temperature continues to rise for
more than 30 min (or above 60°C); if so
there is danger of re! If still possible
safely, move the battery into a space
where a re would not cause harm. Else
evacuate the area.

3 [0x03]

ERROR_UN-

DER_TEMPERATURE

Under-temperature T

ExternalMin

 < Ut

threshold

Clear: No Trigger. Ignition

Board Param
Outdated Error

One of the temperature sensors has
dropped below the minimum tempera-
ture. Disconnect any system causing the
problem. Create an ambient tempera-
ture between 20 and 30°C and wait until
the battery becomes warmer (could take
hours/over night). Never attempt to
charge a battery in an under-temperature
situation!

4 [0x04]

ERROR_OVERLOAD

Overload

SOP=0
Clear: SOP > 80 (%).
Ignition

Current
Outdated Error

Too much current was drawn over too long
a time. Reduce the load connected to
the battery. Program a derating strategy
into the user system, that observes the
"State of Power". Within the continuous
load regime, the SOP is 100%. When peak
loads are drawn, the SOP slowly sinks to
0% and then the overload error is raised.
The speed of SOP reduction is proportion-
al to (I

continuous

-I

measured

30/39

B 6130 - 02-2022 - 1.0en 

HAWE Hydraulik SE

Summary of Contents for IEP 014-CP

Page 1: ...Battery pack type IEP Assembly instructions Translation of the original instructions B 6130 02 2022 1 0 en Ident No IEP 014 CP...

Page 2: ...rand names product names and trademarks are not specifically indicated In particular with regard to registered and protected names and trademarks usage is subject to legal provisions HAWE Hydraulik re...

Page 3: ...11 3 3 Functions 12 3 4 Control 14 3 5 Connector assignment 15 3 6 Number of cycles 15 4 Transport and storage 16 4 1 Transport equipment 16 4 2 Scope of delivery 16 4 3 Checking the delivery 17 4 4...

Page 4: ...achines The manual provides relevant information for the machine manufacturer and machine operator as well as for training courses You can request further information on the product at HAWE Hydraulik...

Page 5: ...cemakers and defibrillators Mandatory signs Protective equipment Safety boots Wear appropriate safety boots to protect your feet against mechanical hazards Work gloves Wear suitable work gloves to pro...

Page 6: ...ctive 2014 30 EU EMC Directive The protective objectives of DIRECTIVE 2014 30 EU are achieved by explicit application of EN 60204 1 section 4 4 2 Electromagnetic Compatibility EMC Documents D 6130 Dat...

Page 7: ...arts at high voltages must be avoided The product satis es protection class IP 65 exclusively when the main connector is connected or engaged Electronic product The product must not be commissioned by...

Page 8: ...ment the new dangers in the complete system s manual Operate product safely Despite safety devices the product still poses residual risks Observe the safety instructions in this manual to reduce healt...

Page 9: ...onal training knowledge and experience so that he she can recognize and avoid dangers that can be caused by electricity Auditor Persons of a technical inspection body who are authorized to perform tes...

Page 10: ...ll type Cell configuration Cells in series nominal voltage Basic type Order coding IEP The order coding can be found on the type plate Type plate The type plate with the manufacturer s contact data ca...

Page 11: ...ep discharge excessive or insufficient temperature and excessive current It performs balancing and optimises the battery s service life The product is available in the following versions IEP 014 CP Th...

Page 12: ...end of the precharge phase the BAT relay closes and precharging ends Default parameters Precharge time 0 65 s Current at end of precharge time 2 A These parameters may be changed without notice during...

Page 13: ...ures measured lie outside the permitted limit values the BMS triggers the opening of the main contactor thereby preventing the ow of current into the battery or from it Integral heater The battery inc...

Page 14: ...t market Make sure that the superordinate system machine can perform the following functions and supplement them in accordance with your own risk assessment The technical data specifications in the da...

Page 15: ...l charge Elevated temperatures and high currents have a negative effect on the cycle life performance IEP 014 CP Set to 3 98 V per cell This guarantees a higher number of cycles If desired the charge...

Page 16: ...s 4 1 Transport equipment DAMAGE Danger for electronic components electrostatic discharge material damage Deliver product in ESD protective packaging DAMAGE Material damage due to mechanical damage Pr...

Page 17: ...ore outdoors Store in an area that is dry and free of dust Protect against sunlight UV radiation dark Storage temperature 0 to 20 C Humidity atmospheric humidity 50 or less Protected against splashed...

Page 18: ...to the hydraulic system while the system is de energized DANGER Risk of injury due to electric shock from the operating capacitor Burns serious injuries or death may result if electromagnetic waves l...

Page 19: ...10 to 20 cm gap between the control cables and power cables Provide separate shields for analogue and digital control lines Tool Voltage tester to EN 61243 3 of at least measurement category CAT III...

Page 20: ...stem at ground potential Route control cables and power cables separately Leave a 10 to 20 cm gap between the control cables and power cables Provide separate shields for analogue and digital control...

Page 21: ...gured please declare this when ordering the battery 6 1 Safety devices and performance limitations Single pole switch off A power relay is installed in the positive wiring path this allows the battery...

Page 22: ...There are a total of four temperature sensors incorporated within the battery these are evaluated and monitored by the Battery Management System BMS If the temperatures in the battery pack exceed de...

Page 23: ...s the requirements set out in Directive 2006 42 EC The product is connected and wired correctly The labels and markings on the higher level machine and the product are easy to see and read The STO fun...

Page 24: ...servation Do not interrupt the charging process at a charge status less than 30 WARNING Risk of electric shock when the cover is open Disregard of this may lead to damage to the battery pack After com...

Page 25: ...ents must only be replaced and connected by trained specialist personnel Obey all applicable electrical safety rules Only connect electric lines to the hydraulic system while the system is de energize...

Page 26: ...only the chargers supplied Do not use any multi way sockets or distributor sockets Do not perform any cleaning work on the device whilst it is being charged DAMAGE Users are not permitted to carry ou...

Page 27: ...ers WARNING Risk of injury through crushing or cutting Body parts might get trapped or cut off between the machine frame and hydraulic system in the event of careless transport installation and de ins...

Page 28: ...service life Defective battery packs can be returned to your service partner contractual dealer or directly to HAWE Mattro GmbH They will ensure the packs are recycled correctly 28 39 B 6130 02 2022...

Page 29: ...e the permitted current range Operate the battery pack within the permitted current range see Current monitoring page 13 Operation outside the permitted temperature range Read the CAN messages Operate...

Page 30: ...Ignition Board Param Outdated Error One of the temperature sensors has exceeded the maximum temperature Disconnect any system causing the problem Create an ambient tempera ture between 0 and 20 C Obs...

Page 31: ...N NECTION Error should not occur during normal operation Try to clear by removing any possible fault in the system connected and cycle ignition 11 0x0B ERROR_P DU_FAILURE PDU failure PDU Open Current...

Page 32: ...r by removing any possible fault in the system connected and cycle ignition 21 0x15 ERROR_OV_SAFE TY_FUSE_TRIGGERED Safety Fuse Triggered Error VmoduleMin FuseTrigger threshold Clear Unclearable Board...

Page 33: ...d detected Feedback is indicating charge contactor is ON but command to discharge contactor is to turn it OFF Clear No Trigger Ignition A weld of the main contactor is detected contactor closed althou...

Page 34: ...reshold Clear No Trigger Ignition Error should not occur during normal operation Try to clear by removing any possible fault in the system connected and cycle ignition 46 0x2E Precharge Resistor Over...

Page 35: ...nstallation not permitted if plug is on top Protection class IP 65 when plugged in or with plug cover closed Vibration resistance Wave form Sinusoidal Frequency Peak value amplitude 7 Hz 18 Hz 1 gn 18...

Page 36: ...charge current duration cell temperature 55 C 220 A Discharge current max 30 s max 5 times per discharge intervals of at least 30 s rest at lower than 80 A cell temperature 55 C 400 A Cell temperature...