www.hawe.de | 2015
09-2015-1.0 - D 7818/1 - EV2S-CAN
27
5.6 Error management
The error code display consists of two displays. Firstly, the text "Er" is displayed, then the display changes to the error number. The
error number is composed of a group and an error. For example, the group represents the analogue input 1 or the temperature error.
The following groups are stored
Group number
Designation
1
Input 1
2
Input 2
3
Output 1
4
Output 2
5
CAN bus
6
Temperature
7
Parameter
8
Other
Error code displayed
Designation
Comment
Er 10
Error Bottom
Cable break detection triggered at input 1
Er 11
Error Top
Short-circuit detection triggered at input 1
Er 12
Error Middle
For twin valves: Before a target value is set, a "zero target value" (joy-
stick middle position) must first exist.
Er 13
Overload current signal
A value greater than 20 mA was measured at input 1 for the current
signal
Er 14
No frequency
PWM signal could not be transmitted, no valid frequency at the input
Er 20
NA
Er 21
NA
Er 22
NA
Er 23
NA
Er 24
NA