22
09-2015-1.0 - D 7818/1 - EV2S-CAN
www.hawe.de | 2015
5.4 Initial operation (quick start)
1. Connect power supply (litz wire/pin 1 and litz wire/pin 2)
2. Switch on power supply
→
Display shows
3. Select number of solenoids
Single-action, twin and 2 single-action solenoids can be selected.
Display
Description
(C-)
No selection, invalid input
(C1)
One single-action solenoid
(C2)
One twin solenoid or two single-action solenoids
(Only possible with EV2S-CAN-DG-L3K)
Operating mode using the
UP
and
DOWN
buttons
Confirm the selected operating mode with
OK
→
Display shows