www.hawe.de | 2015
09-2015-1.0 - D 7818/1 - EV2S-CAN
23
4. Select operating mode
The correct definition of the input signal is crucial for faultless operation. The common variants have been pre-defined.
Display
Input signal
Connection
(t-)
No selection, invalid input
(t0)
0 to 10 V DC
Analogue input 1
(t1)
4 to 20mA
Analogue input 1
(t2)
0 to 10 V DC
Analogue input 2
(t3)
CAN
Analogue input 2
(t4)
PWM
Analogue input 1
(t5)
2 x 0 to 10 V DC
Analogue input 1 & 2
(t6)
-10 to +10 V DC
Analogue input 2
(t7)
0.25 Ubat to 0.75 Ubat
A: 0.49 Ubat to 0.25 Ubat
B: 0.51 Ubat to 0.75 Ubat
Analogue input 1
(t8)
0 to 5 V DC
Analogue input 1
(t9)
0 to 5 V DC
Analogue input 2
Operating mode using the
UP
and
DOWN
buttons
Confirm the selected operating mode with
OK
→
Display shows