8
09-2015-1.0 - D 7818/1 - EV2S-CAN
www.hawe.de | 2015
Temperature-dependent power during continuous operation
Figure 2: °C ambient temperature; I current (mA)
1
12 V systems
2
24V systems
3.3 Communication
CAN bus
CAN protocol
CANopen, J1939
CAN baud rate
10, 20, 50, 100, 125, 250, 400, 500, 800, 1,000 (all units in kBaud)
CAN ID
1 to 127 (Default D = 126)
3.4 Electromagnetic compatibility
The EMC of the device was tested using an accredited testing agency (emitted interference according to EN 61000-6-3 and immunity to
interference according to EN 61000-6-2 evaluation criterion "B"). The test set-ups only represent typical use. This EMC testing does not
release the user from carrying out adequate prescribed EMC testing of their complete system (according to Directive 2004/108/EC). If
the EMC of the complete system must be further amplified, the following measures can be tested and introduced:
•
Supply lines, such as inputs and outputs to and from the device, should be as short as possible. They should be shielded and twisted
in pairs (to reduce the antenna-like effect for increasing the immunity to interference), particularly if used in EMC-loaded applica-
tions.