11.1 Technical data
11.1.1 Operating conditions
Installation position
A 065 Vertical (tank on top)
A 100 Horizontal or vertical (tank on top)
Attachment
Firmly screwed, 2 x M6 on the equipment rack preferably elastic suspension
Pump design
External gear pump
Typical noise
level (distance
1 m, decoupled
attachment)
Motor
A 065 C2D
57 dB(A)
A 100 F2E
57 dB(A)
A 100 A4D
55 dB(A)
A 100 B2D
55 dB(A)
A 100 A4B
55 dB(A)
A 100 R2E
60 dB(A)
Hydraulic uid
Hydraulic uid, according to DIN 51 524 Parts 1 to 3; ISO VG 10 to 68 according to
DIN ISO 3448
Viscosity range: 10 - 500 mm
2
/s
Other media on request
Cleanliness level
ISO
4406
20/18/15
Temperatures
A 065 Environment: approx. -15 to +80 °C, hydraulic uid: +10 to
+40 °C
A 100 Environment: approx. -30 to +80 °C, hydraulic uid: -15 to +80 °C
Pay attention to the viscosity range
Service life
10 years with max. 10,000 cycles
HAWE Hydraulik SE
B 6025 - 12-2021 - 1.1en