Assembly and disassembly
16.1
General notes
Assembly and disassembly work on and with the monitoring unit may only be performed by an
authorised specialist familiar with the safety regulations governing handling electrical
components! When using EX-certified monitoring units in potentially explosive atmospheres, the
professional must also be familiar with the relevant safety regulations!
Before assembly and disassembly disconnect the monitoring unit from the power
supply! Separate plug connections must always be de-energized! If EX-certified
monitoring is operated in a potentially explosive atmosphere, there is otherwise an
explosion hazard, due to spark formation!
The monitoring unit housing must be earthed via the fastening - through the
machine earth of the mounting surface or through a separate protective conductor (PE)!
16.2
Fixing the vibration monitoring unit to the mounting surface
Prerequisites
• Mounting surface is clean and flat; i.e. free of
paint, rust, etc.
• Threaded hole in mounting surface:
15 mm, M8
Tools and material
•
Hex socket key SW 6, SW 8
•
Torque wrench SW 6, SW 8
•
Cylinder head screw with hex socket
M8x20
•
Spring washers for M8
Work steps and instructions
•
Unscrew housing cover from housing
base;
hex socket key SW 8
•
Attach monitoring unit using cylinder
head screws and spring washers with 8
Nm on mounting surface;
Torque wrench SW 6
•
Screw the housing cover back onto the
housing base and tighten to 5 Nm;
Torque wrench SW 8
Fastening on mounting surface (1)
Tighten housing cover with torque wrench (2)
In order to avoid cold welding of the housing cover to the housing base, the
thread is treated ex-works with an assembly paste for stainless steel
connections.