![Hatteland JH 10T06 MMD User Manual Download Page 72](http://html1.mh-extra.com/html/hatteland/jh-10t06-mmd/jh-10t06-mmd_user-manual_2107349072.webp)
72
Communication Interface
IND100084-6
INB100005-1 (Rev 19)
Installation in display
Connectorization
The remote control has two 9 pin D-subs for communication. For systems with more than one
display, the displays are connected together through the unoccupied D-sub. It is regardless which
one is used, with exception for the case described in 2.2.1.2, where COM-1 is connected to
another display, and COM-2 is connected to the pc.
Address
A display’s address is set by a 5-bit dipswitch (red) on the backside of the display, just above the
two D-subs. Only bits 1-4 are currently in use. The position of bit 5 has no effect.
Address is adjusted according to the following table:
Address
Bit 1
Bit 2
Bit
Bit
0
Off
Off
Off
Off
1
On
Off
Off
Off
2
Off
On
Off
Off
3
On
On
Off
Off
4
Off
Off
On
Off
5
On
Off
On
Off
6
Off
On
On
Off
7
On
On
On
Off
8
Off
Off
Off
On
9
On
Off
Off
On
10
Off
On
Off
On
11
On
On
Off
On
12
Off
Off
On
On
13
On
Off
On
On
14
Off
On
On
On
15
On
On
On
On
Selecting communication mode:
Communication mode (U5)
Duplex (U8)
RS-232
RS232
-
RS-485
Full duplex
RS422/485
Full (on)
Half duplex
Half (off)
These settings are normally carried out by JHD before delivery.
Serial Communication (SCOM) Interface
Summary of Contents for JH 10T06 MMD
Page 7: ...INB100005 1 Rev 19 General...
Page 14: ...14 INB100005 1 Rev 19...
Page 15: ...15 INB100005 1 Rev 19 Installation...
Page 20: ...20 INB100005 1 Rev 19...
Page 21: ...21 Operation MMD Products...
Page 35: ...35 INB100005 1 Rev 19 Specifications...
Page 43: ...43 INB100005 1 Rev 19 Technical Drawings...
Page 58: ...58 INB100005 1 Rev 19...
Page 59: ...59 INB100005 1 Rev 19 Technical Drawings Accessories...
Page 68: ...68 INB100005 1 Rev 19...
Page 69: ...69 INB100005 1 Rev 19 Appendixes...
Page 82: ...82 IND100077 24 INB100005 1 Rev 19 Appendix Notes...