7. Installation of the Controls
Route the wire to the starter solenoid on all 12v tractors. Connect the green lead marked
+
to the hot terminal
on the starter. Connect the black lead to a good ground.
Do not reverse the leads.
Be sure to use a
voltmeter to verify that you do have 12 volts running to the box.
Note:
For tractors with 24v starters, connect the power leads to the tractor’s right hand battery. Do not
connect the leads to the starter. Connect the lead to the positive battery terminal and the lead
marked- to the negative on the battery. Wiring connections to the battery normally results in corrosion;
terminal coating is recommended.
Caution:
Do not run a pump or use an electronic control box directly off a battery charger. For stationary use,
the applicator can be connected to a new battery and the battery connected to a charger.