3-10
888-2595-001
12/20/11
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
ZX Series
STEP 5
RF MUTE ACTIVE alarm clears and power ramps up from zero to new
power level.
STEP 6
Consult Section 5 – Maintenance for power adjustment procedure if
power level in new mode is not correct.
STEP 7
Procedure complete.
NOTE:
The power RAISE/LOWER power control setting is preserved while switching
transmitting modes. For example, if the transmitter were operating at 65% of the
maximum FM setting in FM mode, it would transmit at 65% of the maximum HD
setting after switching to HD mode.
3.4.4
Basic Functional Check Procedure
This procedure provides the operator with a basic procedure for assessing the
operational status of the ZX series transmitters. It assumes that the transmitter is
currently switched on.
STEP 1
Check front panel STATUS LED to verify that correct mode is selected
(FM, FM+HD, or HD) and light is green.
GREEN = Amplifier on and no alarms registered
YELLOW = Amplifier on but alarms reported
RED = Amplifier is off
STEP 2
Check forward power reading on front panel multimeter(s) and verify
transmitter is currently at desired power level.
STEP 3
Actuate front panel meter select button to review reverse power, PA
stage voltage, and PA stage current readings.
STEP 4
Compare meter readings to recorded baseline readings.
NOTE:
To facilitate the evaluation of transmitter meter readings, it may be desirable to
attach a small label on or near the transmitter (or inside front door) with the nor-
mal, expected readings for forward power, reverse power, PA volts, and PA amps.
STEP 5
If front panel STATUS LED is not green, open amplifier chassis front
door and perform following checks:
a.
Check alarm LEDs on controller board.
b.
Check status of DC OK lights on PS modules.
Summary of Contents for ZX10
Page 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...