WARNING: Disconnect primary power prior to servicing.
ZX Series
Appendix A - FM Web Remote Option
STEP 2
Note log entry time stamp as compared to quality external clock.
STEP 3
Access configuration page and recalibrate on-board time to correct
value, as desired.
STEP 4
Repeat steps 1 and 2 several hours or several days later.
STEP 5
Note if on-board clock has lost or gained seconds relative to quality
external clock.
STEP 6
Extrapolate rate of gain/loss to 24 hour time period. e.g. 1 sec lost in 12-
hour period = +2 second adjustment required per 24-hour period.
STEP 7
Increment/decrement SEC/DAY time adjustment field on configuration
page.
STEP 8
Recalibrate on-board time to correct value as desired.
STEP 9
Procedure complete.
A.5.6
Use Microchip Discoverer Utility
Purpose:
The USB flash drive supplied with the web remote contains a small
application called Microchip Ethernet Discoverer. This program can be useful for
locating a web remote with an unknown IP address, but is limited to detecting only web
remotes connected to the same subnet. (1:1 PC connection or sharing same router)
Special tools:
Microchip Ethernet Discoverer.exe
Figure A-7 Web discover results window.
Summary of Contents for ZX10
Page 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...