A-16
888-2595-001
12/20/11
WARNING: Disconnect primary power prior to servicing.
ZX Series
Appendix A - FM Web Remote Option
SERIAL NUMBER
The transmitter serial number. This is typically entered in the factory and does not
require updating in the field.
Harris Customer Service may ask you for this number if you call for assistance.
This helps us locate your records.
If the web remote is moved to a new transmitter, be sure to update this field.
MAC ADDRESS
The MAC address of the web remote. This is typically entered in the factory and
does not require updating in the field. A change of this setting could cause a loss
of board connectivity.
CAUTION:
If you need to ask why a MAC address might need to modified, you
should not modify it!
GUEST KEY
The basic level password. This allows access to main web page, but no transmitter
commands. The default guest level password is "guest".
OPERATOR KEY
The main level password. This allows full access to main web page, including the
transmitter command buttons. The default operator level password is "operator".
EXPERT KEY
The administrator level password. This allows access to the configuration web
page. The default expert level password is "expert".
LOW POWER
WARNING
The threshold in watts for the RF < WARN THRESHOLD fault.
NOTE:
This threshold is measured against the system forward power reading, not
the PA forward power reading. This distinction becomes important in larger model
transmitters.
LOW POWER
ALARM
The threshold in watts for the RF < ALARM THRESHOLD fault. This fault con-
dition will cause an SNMP trap and/or e-mail notification to be sent (when
enabled).
NOTE
: This threshold is measured against the system forward power reading, not
the PA forward power reading. This distinction becomes important in larger model
transmitters.
INSTALLED
EQUIPMENT
Allows the web remote to be customized to different transmitter models and sys-
tems by zeroing out those units not installed.
If the ZX System Metering Panel is installed, the SYSTEM FORWARD/
REVERSE POWER readings come from detectors in the metering panel, other-
wise they are repetitions of the PA WATTS readings from the RF detectors inside
the amplifier chassis.
If the Flexstar Main/Alt Switcher is installed, the active exciter status (A/B) is
taken from the switcher. Otherwise, exciter A is reported as active always.
METER CALIBRA-
TIONS
Allows the meter readings to be finely adjusted to compensate for fabrication
tolerances. Individual calibration adjustments are provided for the System
Forward and PA Forward readings. A general calibration factor for all other
readings is also provided.
The calibration factor units are scaled in +/- tenths of a percent.
e.g. -10 = -1.0%, +24 = +2.4%
SNMP GET
ENABLED
Enables the transmitter to be queried by SNMP GET commands.
READ COMMUNITY
The SNMP READ community for GET commands.
SNMP SET
ENABLED
Enables the transmitter to be commanded by SNMP SET commands.
Table A-3 List of settings on configuration page.
Summary of Contents for ZX10
Page 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...