![Harris PT-150C Manual Download Page 50](http://html2.mh-extra.com/html/harris/pt-150c/pt-150c_manual_4877296050.webp)
Module Adapters for the PT/PR-150C
Channel Module Installation Procedure
PT/PR-150C Module Installation & Operation Manual
Harris Corporation
Issue 1, October 2000
Intraplex Products
6-2
6.1
Channel Module Installation Procedure
The PT-150C transmitter and PR-150C receiver modules must be installed with a
module adapter that provides full connectivity to a communication circuit. The
procedure for installing the channel module into a multiplexer with a module
adapter follows.
1.
At Location 1, install and wire the module adapter provided with the channel
module (see Figure 6-1 on page 6-3).
2.
Install the channel module at Location 1.
Caution:
If the ALARM or ALERT indicator on the power supply turns on, remove the
channel module immediately.
3.
Activate the local (equipment) loopback on the channel module and perform
local loopbacks tests.
4.
Before leaving Location 1, be sure to remove the channel loopback. Make
sure that no alarm or alert indicators are on.
5.
At Location 2, install and wire the module adapter provided with the second
channel module.
6.
Install the channel module at Location 2.
Caution:
If the ALARM or ALERT indicator on the power supply turns on, remove the
channel module immediately.
7.
If available, activate the local (equipment) loopback on the channel module
itself and perform local loopback tests on this module (see Appendix A).
8.
Remove the channel loopback.
9.
If desired, perform end-to-end tests or single-ended (far-end loopback) tests
with the other site.
10. Ensure no alarm or alert indicators are on.