Remote Control Interface
IntraGuide Software
PT/PR-150C Module Installation & Operation Manual
Harris Corporation
Issue 1, October 2000
Intraplex Products
3-11
3.5.5
Serial Protocols
The default communications protocols for the common module are:
•
baud rate: 9600
•
data bits: 7
•
parity: odd
•
stop bits: 1
Note:
The settings can be changed, however for long-term ease of use it is
recommended that the communications protocol remain at the system defaults.
3.5.6
Sample Configurations Using IntraGuide
IntraGuide can control the functionality of most cards. The IntraGuide online help
provides context-sensitive information for the operation of the IntraGuide
interface. Figure 3-3 on page 3-11 illustrates the CM-5 configuration interface.
The T1 signaling can be set to B8ZS or AMI. It also provides primary timing
mode and loopback features.
Figure 3-3
CM-5 configuration display
The current condition of the CM-5 can be displayed in the status display shown in
Figure 3-4. This display generates the same report as the manually entered ISiCL
commands discussed previously in this section.