![Harris PT-150C Manual Download Page 18](http://html2.mh-extra.com/html/harris/pt-150c/pt-150c_manual_4877296018.webp)
About the PT-150C and PR-150C
Remote Control Module Address
PT/PR-150C Module Installation & Operation Manual
Harris Corporation
Issue 1, October 2000
Intraplex Products
1-14
1.10
Remote Control Module Address
SW7 sets the SCB Address for the PT-150C and PR-150C. The SCB Address is
used when the module is to be remotely controlled through the multiplexers
REMOTE port.
For remote access, each channel module in an Intraplex multiplexer must have a
unique card address. Valid addresses are the numbers 1 to 36. Determine the
physical slot number of the card and set SW7 according to the settings in
Table 1-9.
Table 1-9
Remote address setting (SW7)
Card
Address
Switch Settings
a
:
SW7 Positions
Card
Address
Switch Settings
a
:
SW7 Positions
5
4
3
2
1
0
5
4
3
2
1
0
1
0
0
0
0
0
1
19
0
1
0
0
1
1
2
0
0
0
0
1
0
20
0
1
0
1
0
0
3
0
0
0
0
1
1
21
0
1
0
1
0
1
4
0
0
0
1
0
0
22
0
1
0
1
1
0
5
0
0
0
1
0
1
23
0
1
0
1
1
1
6
0
0
0
1
1
0
24
0
1
1
0
0
0
7
0
0
0
1
1
1
25
0
1
1
0
0
1
8
0
0
1
0
0
0
26
0
1
1
0
1
0
9
0
0
1
0
0
1
27
0
1
1
0
1
1
10
0
0
1
0
1
0
28
0
1
1
1
0
0
11
0
0
1
0
1
1
29
0
1
1
1
0
1
12
0
0
1
1
0
0
30
0
1
1
1
1
0
13
0
0
1
1
0
1
31
0
1
1
1
1
1
14
0
0
1
1
1
0
32
1
0
0
0
0
0
15
0
0
1
1
1
1
33
1
0
0
0
0
1
16
0
1
0
0
0
0
34
1
0
0
0
1
0
17
0
1
0
0
0
1
35
1
0
0
0
1
1
18
0
1
0
0
1
0
36
1
0
0
1
0
0
a. 1 = Up; 0 = Down