Table 3-2
PR-150C status codes (S codes)
S Code
Binary Digits
Value
Description
7 6 5 4 3 2 1 0
S01
B 0 0 0 0 0 0 0
0
↑
0
No configuration errors
1
Configuration error is present
B 0 0 0 0 0 0
0
↑
0 0
Normal
1
Channel 1 (left) apt-x100 failure
B 0 0 0 0 0
0
↑
0 0 0
Normal
1
Channel 2 (right) apt-x100 failure
B 0 0 0 0
0
↑
0 0 0 0
T1 active
1
E1 active
B 0 0 0
0
↑
0 0 0 0 0
Channel 1 (left) is off
1
Channel 1 (left) is on
B 0 0
0
↑
0 0 0 0 0 0
Channel 2 (right) is off
1
Channel 2 (right) is on
B
0
↑
0
↑
0 0 0 0 0 0 0
Not used
S02
B 0 0 0 0
0
↑
0
↑
0
↑
0
↑
0 or 1
Channel 2 (right) audio input level
B
0
↑
0
↑
0
↑
0
↑
0 0 0 0 0 or 1
Channel 1 (left) audio input level