![Harris CZ1000F Commissioning Manual Download Page 98](http://html1.mh-extra.com/html/harris/cz1000f/cz1000f_commissioning-manual_601186098.webp)
4-8
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 4 RF Testing
4.2.10.4 Power Measurement Procedure
4.2.10.5 Power Measurement Test Results
Step
Procedure Description
Expected Observation
1
Configure the transmitter to operate
on air with Exciter A with
precorrector settings to:
Non-Linear Precorrection = ADAPT
Linear Precorrection = BYPASS
2
Connect the true RMS power meter
probe to the transmitter output
directional coupler (forward port
located before the filter). The
transmitter output should be
connected to the load.
Measured power output is
/- 10% of rated
power
3
Configure the transmitter to operate
on air with Exciter B with
precorrector settings to:
Non-Linear Precorrection = ADAPT
Linear Precorrection = BYPASS
Measured Pout is /-
10% of rated power
Expected Results
Result (circle)
Rated Pout with Exciter A at output of directional couplers.
PASS FAIL
Rated Pout with Exciter B at output of directional couplers.
PASS FAIL
Summary of Contents for CZ1000F
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...