12/24/07
888-2685-001
4-43
WARNING: Disconnect primary power prior to servicing.
Section 4 RF Testing
Ranger Commissioning Manual
4.3.4.2
FSQ Settings
a.
Press the “PRESET” key to restore the FSQ default state.
b.
Recall the “DATA_CAPTURE” state from the FSQ:
1.
Press the “FILE” key on the FSQ
2.
Press the “RECALL” softkey on the FSQ
3.
Select the path to the disk where the state is saved.
4.
Select “DATA_CAPTURE” and select “OK”
5.
Verify the following:
a.
Press “SETUP” key and verify “REFERENCE” is set to “EXT”
b.
RBW = 30kHz
c.
VBW = 300Hz
d.
Attn = 5dB
e.
Ref Lev = -20dBm
f.
Press “TRIG” key and verify the “EXTERN” softkey is selected.
c.
If the FSQ “DATA_CAPTURE” state is not available:
1.
Press the “SETUP” key and then use “REFERENCE” softkey to set to
EXT.
2.
Press the “FREQ” key and enter the desired center frequency using the
number pad and unit selections.
3.
Press the “SPAN” key and enter “10” from the numeric keypad and
terminate the entry with the “MHz” key.
4.
Press the “BW” key. Press the “RES BW MANUAL” softkey and enter
“30 kHz”. Then press the “VIDEO BW MANUAL” softkey and enter
“300 Hz”.
5.
Press the “TRIG” key and then press the “EXTERN” softkey.
4.3.5
Setting Static IP Address for FSQ & Linux Machine
Connect an Ethernet crossover cable between the LAN interface on the rear of the FSQ
and the Linux laptop.
Summary of Contents for CZ1000F
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...