![Harris CZ1000F Commissioning Manual Download Page 112](http://html1.mh-extra.com/html/harris/cz1000f/cz1000f_commissioning-manual_601186112.webp)
4-22
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 4 RF Testing
4.2.14.5 Spurious Emissions Test Results
The following plots show the typical results:
5
Change the following spectrum
analyzer settings:
Start Frequency = 1850 MHz
Stop Frequency = 1990 MHz.
Then measure 1850-1990 MHz
with Exciter A on air.
Less than -38 dBm/100 kHz
6
Change the following spectrum
analyzer settings:
Start Frequency = 1900 MHz
Stop Frequency = 3000 MHz.
Then measure 1900-3000 MHz
with Exciter A on air.
Less than -13 dBm/100 kHz
7
Repeat steps 2-6 with Exciter B
on air.
Results should be consistent with
those from steps 2-6.
Expected results
Result
2nd Harmonic with Exciter A
PASS FAIL
2nd Harmonic with Exciter B
PASS FAIL
3rd Harmonic with Exciter A
PASS FAIL
3rd Harmonic with Exciter B
PASS FAIL
No emission above limit from 847-3000 MHz with Exciter A
PASS FAIL
No emission above limit from 847-3000 MHz with Exciter B
PASS FAIL
Step
Procedure Description
Expected Observation
Summary of Contents for CZ1000F
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...