3.9.3.1
System Setup
This screen provides a way to change important pieces of information which are then
used throughout the GUI. To make a change, simply touch the white text box and a pop-
up window will allow you to enter the new information. Be sure to press CANCEL if
you do not wish to make a change.
a.
Station Name - This can be up to 24 characters and will appear at the top of Every
GUI screen.
b.
Model Number - This value is selected from a pull down list by touching the
white box. The model number chosen must match the transmitter name plate. It is
used to gray out portions of the GUI screens which are not used by some models.
c.
Serial Number - Please note this for reference before calling for support.
d.
Nominal Power Output (after all system filters) - This number is used to:
1.
Set the 100% mark on the power bargraph at the top of every GUI screen.
2.
Calculate the VSWR foldback and fault thresholds, see "3.7.2.1 Output
Setup" on page 3-19.
e.
Channel - Used by the PA module for calibration.
f.
Pilot Frequency - Exact station pilot frequency should be entered in Hz. This
entry has no function and is for informational purposes only.
g.
AC Line (VAC) Nominal - This number should reflect your nominal AC line
voltage as measured at the disconnect.
h.
AC Line Frequency (Hz) - 50 or 60Hz. Should reflect your line frequency.
Figure 3-22 System Setup Screen
To Figure 3-23
To Figure 3-24
To Figure 3-15
To Figure 3-21
Note:
Be sure to press CANCEL
on any pop-up window if
you do not wish to make
any changes. Pressing
DONE without making an
entry will cause the field to
revert to its default and the
previous information will
be lost.
Summary of Contents for CZ1000F
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...