6
GB
General instructions and regulations
Gebruik
• All local regulations including those referring to national and European standards must be observed when using the appliance.
• Ensure that there are no combustible materials in the direct vicinity of the stove.
• Keep the stove closed except when lighting and adding fuel to the appliance, and when removing residual material.
• Parts of the appliance, notably the surface, are hot when touched when the appliance is being used. Take appropriate measures.
• Use firewood that is ±25 cm long and ±7 cm thick. Put it flat on the bottom of the stove. Do not place more than 3 logs in the stove at the
same time. When the fire starts to go down after about 1 hour, add wood.
• Do not use the appliance as a multi-burner. Do not use fuels that are unsuitable or not recommended, and in particular do not use any
liquid fuels.
Maintenance
• Have the appliance serviced regularly by a qualified technician.
• Ensure that the flue-gas connection and the chimney are cleaned regularly.
• Check to ensure that the chimney is still open before lighting the stove again if it has not been used for an extended period of time.
• If, in spite of the precautions taken, there should occur a chimney fire (usually accompanied by a roaring noise in the chimney), proceed
as follows:
- Shut off the air supply and close the door of the stove immediately
- Call the fire brigade
- Quickly extinguish the fire in the stove with sand or soda to prevent smoke from getting into your house
- Ventilate the house
- Never use water to extinguish the fire
• Ensure that after a fire the chimney is first swept and inspected for any damage and leaks.
Service
• It is not allowed to make any modifications to the appliance without prior authorization of the manufacturer.
• Only use replacement parts recommended by the manufacturer.
Declaration
The undersigned, representing the following:
Harrie leenders Haardkachels, Industrieweg 25, 5688 DP, Oirschot, Nederland
herewith declare that the product Doran is in conformity with the provisions of the following EC Directives when installed in accordance with the
installation instructions contained in the product documentation: EN 13240:2001/A2:2004 (E) “Roomheaters fired by solid fuel”
Product: Roomheaters fired by solid fuels as covered under the scope of this standard intended use: Space heating in residential buildings.
Characteristics
Report
Fire safety
EZ/07/1935/01
Emission of combustion products
EZ/07/1935/01
Release of dangerous substance
EZ/07/1935/01
Surface temperature
EZ/07/1935/01
Mechanical resistance (to carry a chimney / flue)
EZ/07/1935/01
Thermal output / energy efficiency
EZ/07/1935/01
Description of the room heater Doran:
Wood stove made of sheet metal. The stove is designed to be placed on the floor and can be rotated 45° to the left and to the right.
It is provided with a door, fixed secondary air supply and controllable window wash air supply. The combustion chamber is
insulated with refractory ceramic elements. The flue-gas connection is located at the top or rear side of the appliance.
Notified body: SGS Environmental Services, Postbus 5252, 6802 EG Arnhem
Reportnumber: EZ/07/1935/01
Manufacturer: Harrie Leenders Haardkachels
Name: Bart Leenders
Position: General Manager
Date: 11-01-2007