4-1 Extension cable
Option
4-4
1
2
4
4
5
6
7
8
9
10
11
Apx
Op
tio
n
EWC-Mxx-A06-NC-M (24VDC specification)
Install the connector supplied with the servo amplifier.
【
Shield line/PE line connections for connector installation
】
When installing the connector supplied with the MR-J4W2-0303B6-MX940J amplifier, connect the
shield line and PE line as follows:
◆
When the actuator connected to the MR-J4W2-0303B6-MX940J amplifier has 1 shaft
◆
When the actuator connected to the MR-J4W2-0303B6-MX940J amplifier has 2 shafts
Pin
No.
Color
Signal
name
1
Blue
Phase A
2
Yellow
Phase B
3
Green
Phase Z
4
Green/Yellow
Shield
PE
Shield
5
6
-
Connect the shield line and PE line to
pin 7 (E2) and pin 9 (E1) on the CNP1
connector and install pin 11 (installation)
on FG.
Shape the shield line and PE line as
shown in the figure on the left and
connect each to pin 7 (E2) and pin 9
(E1) respectively on the CNP1
connector and install pin 11
(installation) on FG.
1
6
7
14
TE Connectivity (AMP)