1-13 Operable range
1-17
1
2
3
4
5
6
7
8
9
10
11
Apx
Ou
tlin
es
100V
Note: If it is used continuously in one direction in the continuous range, please consult with us.
140
120
80
60
20
0
40
100
Rotation speed [r/min]
Torque [Nm]
Radiation plate: 150 x 150 x 6(mm)
■
FHA-11C-50
Input voltage: 100V
10
9
7
5
2
1
0
4
3
6
8
50% duty range
250
200
100
50
0
150
Rotation speed [r/min]
Torque [Nm]
Radiation plate: 150 x 150 x 6(mm)
■
FHA-11C-30
Input voltage: 100V
5.0
4.5
3.5
3.0
1.5
0.5
0
2.0
4.0
2.5
1.0
50% duty range
Continuous
motion range
Continuous
motion range
70
60
40
30
10
0
20
50
Rotation speed [r/min]
50% duty range
Torque [Nm]
Radiation plate: 150 x 150 x 6(mm)
■
FHA-11C-100
Input voltage: 100V
12
10
8
6
2
0
4
Continuous
motion range
Motion range during
acceleration and
deceleration
Motion range during
acceleration and
deceleration
Motion range during
acceleration and
deceleration