13
1018854 8/2018 V03
6. Technical Data
Table 13.3
The continuous operating characteristics given in the following apply to an ambient temperature of 40 °C and an aluminium
cooling surface with the following dimensions:
Series
Size
Version
Unit
Dimensions
CHA
14A
[mm]
200 x 200 x 6
17A
[mm]
300 x 300 x 15
20A
[mm]
300 x 300 x 15
25A
[mm]
350 x 350 x 18
32A
[mm]
350 x 350 x 18
40A
[mm]
400 x 400 x 20
50A
[mm]
500 x 500 x 25
58A
[mm]
600 x 600 x 30
CHA-xxA-E
Table 13.1
Insulation class (EN 60034-1)
F
Insulation resistance (500 VDC)
MΩ
100
Insulation voltage (10 s)
V
rms
600
Lubrication
Flexolub®-A1
Degree of predection (EN 60034-5)
IP65
Ambient operating temperature
°C
0 … 40
Ambient storage temperature
°C
-20 … 60
Relative humidity (without condensation)
%
20 … 80
Vibration resistance (DIN IEC 68 Part 2-6, 10 … 500 Hz)
g
5
Shock resistance (DIN IEC 68 Part 2-27, 18 ms)
g
30
Corrosion protection (DIN IEC 68 Part 2-11 salt spray test)
h
4
Temperature sensors
1 x KTY 84-130 / 1 x PTC
CHA-xxA-H/N
Table 13.2
Insulation class (EN 60034-1)
F
Insulation resistance (500 VDC)
MΩ
100
Insulation voltage (10 s)
V
rms
2500
Lubrication
Flexolub®-A1
Degree of predection (EN 60034-5)
IP65
Ambient operating temperature
°C
0 … 40
Ambient storage temperature
°C
-20 … 60
Altitude (a. s. l.)
m
< 1000
Relative humidity (without condensation)
%
20 … 80
Vibration resistance (DIN IEC 68 Part 2-6, 10 … 500 Hz)
g
5
Shock resistance (DIN IEC 68 Part 2-27, 18 ms)
g
30
Corrosion protection (DIN IEC 68 Part 2-11 salt spray test)
h
4
Temperature sensors
1 x KTY 84-130 / 1 x PTC