9.1 Transport and Storage
The transportation of the servo actuators and motors should always be in the original packaging.
If the servo actuators and motors are not put into operation immediately after delivery, they should be stored in a dry, dust
and vibration free environment. Storage should be for no longer than 2 years at room temperatures (b5 °C ... +40 °C)
so that the grease life is preserved.
INFORMATION
Tensile forces in the connecting cable must be avoided.
ADVICE
Lithium metal batteries are dangerous goods according to UN 3090. Therefore they are generally subject to transport
regulations, depending on the transport mode.
The batteries installed in the motor feedback systems do not contain more than 1 g of lithium or lithium alloy and are exempt
from dangerous goods regulations.
9.2 Installation
Check the performance and protection and check the suitability of the conditions at the installation site. Take suitable con-
structive measures to ensure that no liquid (water, drilling emulsion, coolant) can penetrate the output bearing or encoder
housing.
ADVICE
The installation must be protected against impact and pressure on the gear.
The mounting must be such that heat loss can be adequately dissipated.
No radial forces and axial forces may act to the protection sleeve of the hollow shaft actuator.
During installation, the actuator must be fitted ensuring the machine housing can be rotated without terminals. Already low
terminals may affect the accuracy of the gear and, should this be the case, the installation of the machine housing should be
checked.