AL815CC, AL825, AL825CC, AL835 Hybrid Installation & Owner's Manual 2017
15
TEC00037 2016FEB20 P/N: 630-00053 Rev A
SECTION 2 : INSTALLER
Installation
5. Flip open end connector’s hinged retainer.
Insert
pins as shown.
[Figure 15-1 ]
Verify the wires cannot be pulled out by moderately
pulling on the wires. Be sure rubber seals are inside
the back of the connector.
Close the hinged retainer.
Plug connector into lift.
LETTERS ARE
MOLDED INTO
PLASTIC
HINGED
RETAINER
B
A
BLACK WIRE
RED WIRE
SEALS
B=BLACK
A=RED
RED WIRE
RED WIRE
OR
LAS
T
SIDE MOUNT
TOP MOUNT
6. Last, attach red wire to the positive terminal
on
the battery.
[Figure 15-2]
[Figure 15-1]
[Figure 15-2]
NOTE:
Troubleshooting with a test light or voltage meter may give a false indication.
When you probe for 12 volts, the reading may indicate a connection, even if the connection is not necessarily
sufficient. The lift’s motor can draw up to 30 amps at some points, requiring all of the available wire to flow
proper current. Poor connections are the #1 problem associated with a slow,
intermittent, warm, poorly performing motor which will also deteriorate
prematurely.
If a single strand of a multi-strand wire is making contact, 12V will appear on a
meter or test light, but it will not allow the motor to operate. It is always best to
test both current and voltage, or run the motor with known good shop battery or
power source when troubleshooting.