INSTALLATION (Options)
Only For Qualified Installers
Connecting an
Optional Thermostat
If an optional thermostat is used, it must be plugged
into the terminal strip located in the lower left front
corner of the heater.
When installing a millivolt control system, use only
a special low resistance thermostat. DO NOT USE
A REGULAR HEATING THERMOSTAT.
Be sure that all electrical connections are clean,
free from corrosion, and tight. Inspect connections
periodically to confirm that no corrosion has built
up over time.
When properly installed and maintained, a millivolt
control system should give many years of trouble-
free service.
It is important to use wire of a gauge proper for the
length of the wire:
RECOMMENDED WIRE GAUGES
Maximum
Wire
Length
Gauge
100’
14
60’
16
40’
18
25’
20
15’
22
Thermostat
Remote Control
The front button on the remote control can be used
to turn the front burner on and off. The rear button
is used to turn the rear burner on and off.
This remote uses the ultrasonic control method and
does not need to be pointed directly at the fireplace.
A hand held sending unit, receiving unit, mounting
bracket and all wiring are included when you order
the remote control.
Installation instructions are packed with remote kit.