9
SPECIFICATIONS
Accordion Heat
Exchanger
Vent Collar
Brick
Blower
Battery
Pack
Rear Burner
Switch
Hi-Low Knob
On-Off-Pilot Knob
Ignitor
Blower Speed Switch
On-Off- Thermostat
Switch
Burner Module
Electrical Box
Glass Door
Top Standoffs
raTIngS
NATURAl PRoPANe
Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m)
43500
43500
Min. Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m)
23300
23800
orifices (DMS)(front/rear)(0-4500 ft.)(0-1375 m)
31/51
52/59
Manifold Pressure (in w.c./kPa)
3.5/0.87
10.0/2.49
Min. Manifold Pressure (in w.c./kPa)
1.7/0.42
6.3/1.6
Min. Inlet Pressure (in w.c./kPa)
5.0/1.25
11.0/2.74
Max. output (Btu/hr)(0-4500 ft.)(0-1375 m) (Blower off) 31500
32000
Max. efficiency (Blower on)
84.5%