10
When installing and operating your Harman Accentra
Pellet Stove, respect basic safety standards. Read these
instructions carefully before you attempt to install or oper-
ate the Accentra. Failure to do so may result in damage
to property or personal injury and may void the product
warranty.
Several issues must be addressed when selecting a
suitable location for your Accentra Pellet Stove. Observing
required clearances to combustible materials, the proximity
to a safe chimney or venting system, and the accessibil-
ity of electrical supply must all be considered. In addition,
selecting a location that takes advantage of the building's
natural air flow is also desirable to maximize the heating
effectiveness of the heater. In many cases, this is a central
location within the building.
Place the stove on a noncombustible floor surface or floor
protector. This can be a minimum of a 20 gauge sheet metal
plate, ceramic tile with grouted joints, a UL listed stove
board, or a Harman Cast Iron floor protector
1
. The Harman
Cast Iron Floor Protector is equal to the minimum dimensions
,
which are 24
1
/
16
x 28
5
/
8
1.
This allows for a 2" extension on
each side of the unit (which is actually
6 inches from the
window
opening) and a 6" extension to the front (measured
from the window
opening also) (3
3
/
8
"
2
if measured from the
base plate front edge.) The rear edge of the floor protection
can be flush with the cast base plate rear edge.
Place the stove away from combustible walls at least as
far as shown in figures 10, 11, & 13. Minimum clearance
to a ceiling above the heater is 24".
Note that the clearances shown are minimum for safety
but do not leave much room for access when cleaning or
service is needed.
CAuTION
The stove is hot while in operation.
Keep children, clothing and furniture away.
Contact may cause skin burns.
Installation
2"
Fig.12
FLOOR
PROTECTOR
1
6"
2
2"
24
1
/
16
"*
28
5
/
8
"*
Fig.11
2.25"
12"
Fig.10
6.25"
6.25"
5"min
3
5"min
3
This is the minimum size Harman
recommends for the alcove with a 60" ceiling.
54"
2.25"
14.75"
14.75"
24"
Fig. 13
1. Check your local codes to see if protection is required under the
flue pipe.
2. This measurement equals 6" from inside edge of ash door
opening.
3. 5" pipe clearance to wall in a corner installation.
(*Harman Cast Iron Floor Protector size.)
0"
2"
INSTAll vENT AT ClEArANCES SPECIFIEd
bY ThE vENT mANuFACTurEr.
dO NOT uSE mAKEShIFT COmPONENTS
Or COmPrOmISES whEN INSTAllINg ThIS
APPlIANCE. YOur SAFETY IS A SErIOuS
CONCErN.
dO NOT CONNECT ThIS rOOm hEATEr TO
ANY AIr dISTrIbuTION duCT Or SYSTEm.