23
recommended once per month or after each ton
of pellets burned:
1. Remove the two heat exchanger covers. See Fig.
35. These covers are made of cast iron and are held
into place with a swing latch in the upper right and left
corners. See Fig 36. Swing the latch upward far enough
to release the top edge of the heat exchanger cover.
Tilt the cover forward approximately 2" and lift it upward
about 1" to release the bottom edge. The cover can
now be taken completely out through the upper door
opening. Repeat the process with the second heat
exchanger cover.
(Continued next page;)
maintenance - Cleaning
Heat Exchanger cover latch
Fig. 36
Cleaning Internal Components
Feeder Chamber
This chamber may get a buildup of fines from the
feeder mechanism movement. This area should be
checked and cleaned at least
once a year.
To remove the feeder cover:
•
Remove the (2) 5/16" wing nuts.
•
Slide the cover off of the threaded studs.
•
Inspect and clean the inner chamber if necessary.
See above picture.
•
Reinstall the cover making certain it is centered on
the feeder body and tighten the wing nuts as tightly
as you can by hand.
Possible pellet fines
buildup area.
Fig. 35
Ash removal
Due to potential high temperatures, it is recommend-
ed that the stove be out and cool prior to removing the
ash pan. Open the front door and grasp the ash pan
by the handle. With the ash pan removed, swing the
handle upward for carrying.
disposal of Ashes- Ashes should be placed in a
metal container with a tight fitting lid. The closed
container of ashes should be placed on a non-
combustible floor or on the ground, well away
from all combustible materials, pending final
disposal. If the ashes are disposed of by burial in
soil or otherwise locally dispersed, they should be
retained in the closed container until all cinders
have been thoroughly cooled.