Oakleaf Woodburning Stove

Dry Seasoned Wood Only!

Harman®  •  Oakleaf Owner's Manual_R23  •  2010 -___  •  09/15

4

3-90-798

A. Appliance Certification

E. BTU & Efficiency Specifications

Listing and Code Approvals 

B. Mobile Home Approved

This  appliance  is  approved  for  Installation  in  mobile/

manufactured  homes  in  the 

US only

.  The  structural 

integrity of the mobile home floor, ceiling and walls must be 

maintained. The  appliance  must  be  properly  grounded  to 

the frame of the mobile home, and must never be installed 

in  a  room  designated  for  sleeping.  The  unit  must  have 

provisions  for  an  outside  air  source  when  installed  in  a 

mobile home.

C. Glass Specifications

This  appliance  is  equipped  with  5mm  ceramic  glass. 

Replace glass only with 5mm ceramic glass. Please contact 

your dealer for replacement glass if needed.

D. Electrical Rating

Optional Blower: 115 VAC, 60 Hz. <1 Amps

The Oakleaf Woodburning Stove is Certified 

to  comply  with  2015  particulate  emission 

standards. Not approved for sale after May 

15, 2020.

MODEL:

Oakleaf Woodburning Stove

LABORATORY:

OMNI Test Laboratories, Inc

REPORT NO.

135-S2-26-6.2

TYPE:

Solid Fuel Room Heater / Wood 

Burning Type

STANDARD(s):

UL1482-10, & ULC S627-00

EPA 

Method 28 & 5G

ELECTRICAL 

RATING:

115 VAC, 60 Hz

EPA Certification Number:

898

EPA Certified Emissions:

2.2 g/hr

*LHV Tested Efficiency:

63%

**HHV Tested Efficiency:

70.9%

***EPA BTU Output:

9,700 - 24,600

****BTU Input

45,100

Vent Size:

6 Inch

Recommend Log Lenght:

18" Maximum

Fuel

Seasoned Cord Wood

*  Weighted  average  LHV  efficiency  using  data  collected 

during EPA emissions test.
**Weighted  average  HHV  efficiency  using  data  collected 

during EPA emissions test.
***A range of BTU outputs based on EPA Default Efficiency 

and the burn rates from the low and high EPA tests.
****Based  on  the  maximum  burn  rate  multiplied  by 

approximately 8600 BTU’s which is the average BTU’s per 

pound of wood with an average moisture content of 20%.

This wood heater needs periodic inspection and repair for 

proper operation. It is against federal regulations to operate 

this  wood  heater  in  a  manner  inconsistent  with  operating 

instructions in this manual.

Summary of Contents for Oakleaf

Page 1: ...to installation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requireme...

Page 2: ...origine am ricaine et pi ces import es E F F E REFER TO MANUFACTURER S INSTRUCTIONS FOR CLEARANCES WITH ADDITIONAL VENT CONFIGURATIONS US ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015...

Page 3: ...Component Locator 7 D Flue Direction Conversion 7 E Pre Use Checklist 8 4 Dimensions Clearances A Appliance Dimensions 9 B Clearances to Combustibles 10 C Floor Protection 12 5 Chimneys and Venting A...

Page 4: ...n standards Not approved for sale after May 15 2020 MODEL Oakleaf Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S2 26 6 2 TYPE Solid Fuel Room Heater Wood Burning Type STANDARD...

Page 5: ...se ventilation by opening windows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox if ne...

Page 6: ...eded to replace what the chimney draws away through the appliance B Fire Safety Maintain the designated clearances to combustibles Insulation must not touch the chimney You must maintain the designate...

Page 7: ...ing upward through the firebox and the open bypass damper loosen the retainer bolts on each of the flue collar and the cast iron plate With the bolts loosened turn the retainer to allow the piece to c...

Page 8: ...clean if applicable 12 The optional air distribution blower has been installed properly 13 A properly grounded electrical receptacle is available within reach of the blower s power cord if installed...

Page 9: ...27 1 4 692mm 29 1 4 743mm 18 15 16 480mm 25 5 8 650mm Centered 27 5 8 701mm When configured for rear flue Floor to center of flue measures 23 1 2 597mm NOTICE When using rear flue configuration a new...

Page 10: ...to single wall connector pipe This lower clearance is based on actual safety test conditions E D B C A E F C A C A D B Vertical Venting Configuration Location Single Wall Pipe A Unit to Side Wall 17...

Page 11: ...Shield Corner to Wall 14 356mm B Vent Pipe to Wall 21 3 4 552mm Location Single Wall Pipe A Shield Corner to Wall 14 356mm B Vent Pipe to Wall 21 3 4 552mm Location Single Wall Pipe A Unit to Side Wa...

Page 12: ...floor protection USA is 32 5 16 Wide By 43 3 8 Deep Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to...

Page 13: ...through an attic or roof space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall...

Page 14: ...he highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10 ft 3m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point...

Page 15: ...our plans See Clearances and Floor Protection in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fi...

Page 16: ...ace a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm collar Roof flashing Roof radiation shield SS...

Page 17: ...thimble Flue liner with required air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non...

Page 18: ...ld The Chimney Connector Shall Not Pass Through an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Combustible Floor Airtight insulated clean out Flue liner with required air...

Page 19: ...ll Not Pass Through an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Combustible Floor UL1777 Stainless steel liner system or other approved lining system Floor Protection F...

Page 20: ...pace a Floor or Ceiling Minimum clearance from chimney connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 c...

Page 21: ...or protection requirements must be followed 6 Follow the vent manufacturer s instructions when installing in a mobile home 7 Installation shall be in accordance with the Manufactured Home and Safety S...

Page 22: ...wall portion 6 Slide the other end of the metal intake flex pipe into the stub on the rear of the Oakleaf and secure it with aluminum tape This air intake will supply outside air for the secondary co...

Page 23: ...er on at any time using the rocker switch on the rear of the blower housing Setting the switch to AUTO will keep the blower off until there is a significant amount of heat from the stove In this setti...

Page 24: ...perating guidelines you will ensure proper draft and gain maximum efficiency and enjoyment from your stove Do not alter the position of the andirons Building a fire too close to the glass may cause da...

Page 25: ...he ash to fall into the ash pan by passing a poker back and forth across the grate The andirons keep the fuel from coming into direct contact with the glass and keep hot coals and embers from spilling...

Page 26: ...epaper and close the loading door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making su...

Page 27: ...The ashes should be the coolest at this time Remove ashes from the fire chamber periodically by raking a poker across the bottom grates Excessive ash buildup can prevent proper venting of exhaust gas...

Page 28: ...chnician A Creosote Formation and Need For Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condens...

Page 29: ...eplace gasket as needed Do not operate the stove with a broken glass Replacement glass which is ceramic glass should be obtained only through your Harman dealer To replace a broken glass first be sure...

Page 30: ...dust and pet hair from the blower wheel Reinstall the blower and tighten the two bolts securely 5 Chimney Connector Frequency As necessary Yearly By Qualified Service Technician User At the end of the...

Page 31: ...kleaf Owner s Manual_R23 2010 ___ 09 15 31 3 90 798 Variable Speed Switch Power Cord Blower Thermostat Rocker Grounded to housing Switch Black Wire White Wire 2 1 Oakleaf Optional Blower Kit 1 00 7970...

Page 32: ...acturing Date Active Part number list on following page Cast Iron Wood Stove 1 90 797000 1 Black Sept 2010 thru June 2011 1 90 797000 2 Charcoal 1 90 797000 3 Golden re 1 2 7 6 8 23 22 3 4 5 28 27 26...

Page 33: ...7 Oakleaf Package 3 40 797022 Y Gasket 1 4 Round PSA 15 FT 1 00 2312 Y 8 Ramp Assembly w Gsket 1 10 797109 Y Gasket 1 4 Round PSA 15 FT 1 00 2312 Y 9 Brick Clip Set 1 00 249153 Y 10 Damper Frame Asse...

Page 34: ...50 3 30 1134 50 Y Bolt CB 5 16 18 X 2 Z Pkg of 25 3 30 4001 25 Y Nut FHN 5 16 18 Z 5 Pkg of 100 3 30 8005 100 Y 21 Base Plate Qty 2 req 2 00 797027S 22 Center Brick 3 40 797020 Y Gasket 1 4 Round PSA...

Page 35: ...anty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warrant...

Page 36: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Page 37: ...Oakleaf Woodburning Stove Dry Seasoned Wood Only Harman Oakleaf Owner s Manual_R23 2010 ___ 09 15 37 3 90 798 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 38: ...__________________ ________________________________________________________________________________ ________________________________________________________________________________ ___________________...

Reviews: