Harman Oakleaf Owner'S Manual Download Page 22

Oakleaf Woodburning Stove

Dry Seasoned Wood Only!

Harman®  •  Oakleaf Owner's Manual_R23  •  2010 -___  •  09/15

22

3-90-798

A. Outside Air Attachment

Parts and Supplies Needed from Local Hardware Stove: 1 

piece of 4 in. (4.5 in. OD) aluminum flex dryer vent (4 in. 

rigid aluminum duct is not a suitable substitute and will not 

work) x needed length, 1 rodent screen, aluminum tape and 

a trim ring for finished around the outside air pipe inside the 

home. 
1.  Determine  an  appropriate  hole  location,  through  the 

wall.  Be  sure  there  are  no  studs  or  other  supporting 

members. Also ensure there are no electrical wires or 

plumbing contained within the wall. 

2.  Make  the  hole  through  the  exterior  wall  using  a  hole 

saw or reciprocating saw. You'll want the hole to be just 

slightly larger than the metal flex pipe.

3.  Attach  the  rodent  screen  to  one  end  of  the  flex  pipe, 

and insert it through the wall until the back of the screen 

cover is against the outside surface. 

4.  Hold  the  flex  pipe  in  place  to  make  an  accurate 

determination  of the length needed. Cut the flex pipe 

to length.

5.  Slide the trim ring onto the flex for the inside wall portion.
6.  Slide  the  other  end  of  the  metal  intake  flex  pipe  into 

the stub on the rear of the Oakleaf and secure it with 

aluminum tape. This air intake will supply outside air for 

the secondary combustion within the FireDome.

7.  Secure the trim ring in place for finishing the inside wall 

area.

8.  Seal  around  the  rodent  screen  on  the  exterior  wall, 

using silicone caulking.

B. Leveling the Appliance

To adjust the leveling bolts, you must first loosen the locking 

nut. Turn the leveling bolt to the desired position, and tighten 

the locking nut against the cast iron leg. 

C. Optional Cooking Grill

The optional cooking grill #1-00-08121 installs easily in the 

top load opening of the Oakleaf. 
The  grill  handle  (B)  fits  in  the  slots  (C)  on  each  side.  To 

remove the handle, lower and turn.
When installed, the grill hangs in the opening by the hooks 

(A).
When  grilling,  you'll  want  to  keep  the  fire  size  small  and 

the bypass damper in the open position. Depending on the 

grilling  being  done,  you  may  get  grease  dripping  on  the 

glass causing it to become dirty and obstructed. When you 

burn your next hot fire, the glass will likely clean itself.

Appliance Set-Up 

NEVER DRAW OUTSIDE COMBUSTION AIR FROM:

•  WALL, FLOOR OR CEILING CAVITY.

•  ENCLOSED SPACE SUCH AS AN ATTIC OR GARAGE

CAUTION

!

A

A

A

B

C

C

Outside Air 

Attachment

Summary of Contents for Oakleaf

Page 1: ...to installation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requireme...

Page 2: ...origine am ricaine et pi ces import es E F F E REFER TO MANUFACTURER S INSTRUCTIONS FOR CLEARANCES WITH ADDITIONAL VENT CONFIGURATIONS US ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015...

Page 3: ...Component Locator 7 D Flue Direction Conversion 7 E Pre Use Checklist 8 4 Dimensions Clearances A Appliance Dimensions 9 B Clearances to Combustibles 10 C Floor Protection 12 5 Chimneys and Venting A...

Page 4: ...n standards Not approved for sale after May 15 2020 MODEL Oakleaf Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S2 26 6 2 TYPE Solid Fuel Room Heater Wood Burning Type STANDARD...

Page 5: ...se ventilation by opening windows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox if ne...

Page 6: ...eded to replace what the chimney draws away through the appliance B Fire Safety Maintain the designated clearances to combustibles Insulation must not touch the chimney You must maintain the designate...

Page 7: ...ing upward through the firebox and the open bypass damper loosen the retainer bolts on each of the flue collar and the cast iron plate With the bolts loosened turn the retainer to allow the piece to c...

Page 8: ...clean if applicable 12 The optional air distribution blower has been installed properly 13 A properly grounded electrical receptacle is available within reach of the blower s power cord if installed...

Page 9: ...27 1 4 692mm 29 1 4 743mm 18 15 16 480mm 25 5 8 650mm Centered 27 5 8 701mm When configured for rear flue Floor to center of flue measures 23 1 2 597mm NOTICE When using rear flue configuration a new...

Page 10: ...to single wall connector pipe This lower clearance is based on actual safety test conditions E D B C A E F C A C A D B Vertical Venting Configuration Location Single Wall Pipe A Unit to Side Wall 17...

Page 11: ...Shield Corner to Wall 14 356mm B Vent Pipe to Wall 21 3 4 552mm Location Single Wall Pipe A Shield Corner to Wall 14 356mm B Vent Pipe to Wall 21 3 4 552mm Location Single Wall Pipe A Unit to Side Wa...

Page 12: ...floor protection USA is 32 5 16 Wide By 43 3 8 Deep Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to...

Page 13: ...through an attic or roof space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall...

Page 14: ...he highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10 ft 3m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point...

Page 15: ...our plans See Clearances and Floor Protection in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fi...

Page 16: ...ace a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm collar Roof flashing Roof radiation shield SS...

Page 17: ...thimble Flue liner with required air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non...

Page 18: ...ld The Chimney Connector Shall Not Pass Through an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Combustible Floor Airtight insulated clean out Flue liner with required air...

Page 19: ...ll Not Pass Through an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Combustible Floor UL1777 Stainless steel liner system or other approved lining system Floor Protection F...

Page 20: ...pace a Floor or Ceiling Minimum clearance from chimney connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 c...

Page 21: ...or protection requirements must be followed 6 Follow the vent manufacturer s instructions when installing in a mobile home 7 Installation shall be in accordance with the Manufactured Home and Safety S...

Page 22: ...wall portion 6 Slide the other end of the metal intake flex pipe into the stub on the rear of the Oakleaf and secure it with aluminum tape This air intake will supply outside air for the secondary co...

Page 23: ...er on at any time using the rocker switch on the rear of the blower housing Setting the switch to AUTO will keep the blower off until there is a significant amount of heat from the stove In this setti...

Page 24: ...perating guidelines you will ensure proper draft and gain maximum efficiency and enjoyment from your stove Do not alter the position of the andirons Building a fire too close to the glass may cause da...

Page 25: ...he ash to fall into the ash pan by passing a poker back and forth across the grate The andirons keep the fuel from coming into direct contact with the glass and keep hot coals and embers from spilling...

Page 26: ...epaper and close the loading door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making su...

Page 27: ...The ashes should be the coolest at this time Remove ashes from the fire chamber periodically by raking a poker across the bottom grates Excessive ash buildup can prevent proper venting of exhaust gas...

Page 28: ...chnician A Creosote Formation and Need For Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condens...

Page 29: ...eplace gasket as needed Do not operate the stove with a broken glass Replacement glass which is ceramic glass should be obtained only through your Harman dealer To replace a broken glass first be sure...

Page 30: ...dust and pet hair from the blower wheel Reinstall the blower and tighten the two bolts securely 5 Chimney Connector Frequency As necessary Yearly By Qualified Service Technician User At the end of the...

Page 31: ...kleaf Owner s Manual_R23 2010 ___ 09 15 31 3 90 798 Variable Speed Switch Power Cord Blower Thermostat Rocker Grounded to housing Switch Black Wire White Wire 2 1 Oakleaf Optional Blower Kit 1 00 7970...

Page 32: ...acturing Date Active Part number list on following page Cast Iron Wood Stove 1 90 797000 1 Black Sept 2010 thru June 2011 1 90 797000 2 Charcoal 1 90 797000 3 Golden re 1 2 7 6 8 23 22 3 4 5 28 27 26...

Page 33: ...7 Oakleaf Package 3 40 797022 Y Gasket 1 4 Round PSA 15 FT 1 00 2312 Y 8 Ramp Assembly w Gsket 1 10 797109 Y Gasket 1 4 Round PSA 15 FT 1 00 2312 Y 9 Brick Clip Set 1 00 249153 Y 10 Damper Frame Asse...

Page 34: ...50 3 30 1134 50 Y Bolt CB 5 16 18 X 2 Z Pkg of 25 3 30 4001 25 Y Nut FHN 5 16 18 Z 5 Pkg of 100 3 30 8005 100 Y 21 Base Plate Qty 2 req 2 00 797027S 22 Center Brick 3 40 797020 Y Gasket 1 4 Round PSA...

Page 35: ...anty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warrant...

Page 36: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Page 37: ...Oakleaf Woodburning Stove Dry Seasoned Wood Only Harman Oakleaf Owner s Manual_R23 2010 ___ 09 15 37 3 90 798 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 38: ...__________________ ________________________________________________________________________________ ________________________________________________________________________________ ___________________...

Reviews: