Oakleaf Woodburning Stove
Dry Seasoned Wood Only!
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15
2
3-90-798
Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become
part of our commitment to meeting the heating needs of consumers with the most distinctive, powerful and responsible home
heating products available.
The Oakleaf has huge features in an elegantly small package, The Oakleaf takes advantage of Harman’s 30+ years of stove
design, technology and manufacturing. The Firedome secondary combustion system provides for super-clean burning and
minimal maintenance. The top-loading feature makes for more convenient loading, with enough fuel for an all day burn.
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance.
Thank you for choosing Harman.
This Label is located on the rear of the appliance. It contains important safety test information as well as the clearances to
combustible materials. The label also contains the appliance serial number. For your records, copy your serial number and
purchase date here.
Serial #: ________________________
Date of Purchase: ________________________
Approved For Use in Mobile/Manufactured Homes (UM) 84-HUD -
USA ONLY
“PREVENT HOUSE FIRES”
Install and use only in accordance with manufacturer’s installation
and operation instructions and local codes. In absence of local codes, installation must meet
minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for
precautions required for passing chimney through a combustible wall or ceiling.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s
manual for further information. It is against federal regulations to operate this wood heater in a manner
inconsistent with the operating instructions in the owner’s manual.
WARNING: FOR MANUFACTURED HOMES:
(US Only) Do not install appliance in a sleeping room.
An outside air inlet must be provided. The structural integrity of the manufactured home’s floor, walls,
and ceiling must be maintained.
Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be factory built
103HT or masonry construction. Contact Local Building or Fire Officials about restrictions and
installation inspection in your area.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SERVING ANOTHER APPLIANCE.
FOR USE WITH SOLID WOOD FUEL ONLY, DO NOT bURN COAL.
EPA Certified Emissions: 2.2 g/hr
Fuel Type:
Cord Wood
DO NOT Overfire - If Heater or chimney connector glows, you are overfiring.
Optional Blower Harman #1-00-797032: Electrical Rating 115 VAC, 60Hz, 1AMP Maximum
Route power cord away from unit.
OPERATE ONLY WITH DOORS CLOSED
Replace glass only with 5mm ceramic, available from your dealer.
Combustible flooring must be protected with an approved 0.45R hearth board.
Appliance must be
installed with the legs attached. Do not obstruct
airflow under the
appliance.
DANGER: Risk of Fire
or Explosion - Do not burn garbage, gasoline,
drain oil or other
flammable liquids.
WARNING: Risk of
Fire, Do not operate with fuel loading or ash
removal doors open.
Do not store fuel or
combustibles within marked clearances. Inspect
and clean chimney and connector regularly - Under certain conditions of use, creosote
buildup may occur rapidly.
The Bypass Damper must be opened prior to opening any load or ash door.
Do not install a grate or otherwise elevate the fire.
DO NOT REMOVE THIS LABEL / Ne pas enlever cette étiquette
352 Mountain House Road
Halifax, PA 17032
ECO:
PARt # / REv: 3-90-797_RevD
ORiginAtOR: Spidlet
DAtE: 04/15
LAbEL SizE: 15.5 in. x 5.875 in.
LOCAtiOn:
CLASS:
ADHESivE:
468
MAtERiAL:
MEtAL
ink: bLACk
OvERCOAt:
LAbEL tiCkEt
(4) Hole Size = .60
(1) Hole Size = .125
(1) Hole Size = .125 x .25
Corners .062
CLEARANCE TO COMbUSTIbLES
DISTANCES MINIMALES DE SECURITE:
P.N. 3-90-797
CAUTION:
HOT wHIle IN OperATION. DO NOT TOUCH.
Keep CHIlDreN AND ClOTHINg AwAy. CONTACT mAy CAUse sKIN
bUrNs. see NAmeplATe AND INsTrUCTIONs. Keep fUrNIsHINgs
AND OTHer COmbUsTIble mATerIAls A CONsIDerAble DIsTANCe
AwAy frOm THIs ApplIANCe.
ATTeNTION:
CHAUD lOrs DU fONCTIONNemeNT. Ne
TOUCHeZ pAs l’AppAreIl.gArDeZ les eNfANTs eT les VÊTemeNTs ÉlOIgNÉs. TOUT
CONTACT peUT eNTrAÎNer Des brÛlUres De lA peAU. rÉfÉreZ-VOUs À lA plAQUe
sIgNAlÉTIQUe eT AU mODe D’emplOI. gArDeZ le mObIlIer eT les AUTres mATÉrIAUX
COmbUsTIbles bIeN À l’ÉCArT De l’AppAreIl.
A
C
D
b
Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-
d’Amérique par des pièces d’origine américaine et pièces importées.
E
F
F
E
REFER TO MANUFACTURER’S INSTRUCTIONS FOR CLEARANCES WITH
ADDITIONAL VENT CONFIGURATIONS.
US ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.
Certifié conforme aux normes 2015 d’émission de particules. Non approuvé pour la vente après le 15 mai 2020.
BARCODE LABEL
008
Serial No.
N
o
de série:
Rev D
Report #/ Raport #
135-S-26-6.2
Tested to / Testé à:
UL1482-10, and ULC-S627-00, EPA Method 28 & 5G
Approuvé pour l'utilisation dans les maisons mobiles / Fabricant -
USA SEULEMENT
"EMPêCHER MAISON INCENDIES"
Installer et utiliser uniquement en conformité avec
installation et d'utilisation les instructions du fabricant et les codes locaux. En l'absence de
codes locaux, l'installation doit satisfaire aux exigences minimales de la norme NFPA 211
aux Etats-Unis. Reportez-vous aux instructions du fabricant et les codes locaux pour les précautions nécessaires pour faire
passer la cheminée à travers un mur ou un plafond combustible.
Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct. Consultez le manuel du
propriétaire pour plus d'informations. Ce est contre les règlements fédéraux pour faire fonctionner ce poêle à bois d'une
manière incompatible avec les instructions d'utilisation dans le manuel du propriétaire.
AVERTISSEMENT: POUR maisons préfabriquées:
(États-Unis uniquement) Ne pas installer l'appareil dans une chambre
à coucher. Une entrée d'air extérieur doit être fournie. L'intégrité structurale du sol, les murs et le plafond de la maison
préfabriquée doit être maintenue.
Tuyau de raccordement de fumée doit être de 6 "de diamètre, en acier au minimum 24 MSG bleu. Cheminée doit être
construite l'usine 103HT ou la construction de maçonnerie. Contactez Immeuble Local ou fonctionnaires incendie au sujet
des restrictions et l'inspection d'installation dans votre région.
NE PAS brancher l'appareil à une cheminée desservant un autre APPAREIL.
Pour une utilisation avec Solid combustible bois Seulement, Ne pas brûler de charbon.
Émissions certifiés EPA: 2,2 g / h
Type de carburant: Cordon bois
NE SURCHAUFFEZ - Si le connecteur chauffe ou de la cheminée rougeoie, vous surchauffez.
Facultatif Blower Harman # 1-00-797032: Note électrique 115 VAC, 60Hz, 1AMP maximum
Route cordon électrique de l'appareil.
FONCTIONNER UNIqUEMENT AVEC LES PORTES FERMÉES
Remplacer le verre seulement avec de la céramique 5mm, disponible chez votre revendeur.
Plancher combustible doit être protégé par un conseil 0.45R foyer approuvé.
L'appareil doit être installé avec les jambes attachées. Ne pas obstruer le flux d'air sous l'appareil.
DANGER: risque d'incendie ou d'explosion - Ne pas brûler de déchets, de l'essence, vidanger l'huile ou d'autres
liquides inflammables.
AVERTISSEMENT: Risque d'incendie, ne pas fonctionner avec chargement de combustible ou d'enlèvement de
cendres portes ouvertes.
Ne pas stocker carburants ou de combustibles dans les dégagements marqués. Inspectez et cheminée propre et
le connecteur régulièrement - Dans certaines conditions d'utilisation, l'accumulation de créosote peut se produire
rapidement.
Le Bypass amortisseur doit être ouvert avant d'ouvrir ne importe quelle porte de charge ou de la cendre.
Ne pas installer une grille ou autrement surélever le feu.
MODEL / MODÈLE: “OAKLEAF” Woodburning Stove
Room Heater Solid Fuel Burning Type
SUITABLE FOR MOBILE-HOME INSTALLATION (USA ONLY)
C
D
b
A
Parallel Installation
Inches Millimeters
Back Wall / Entre mur arriereet l’appareil
Side Wall To Unit / Entre mur lateral et l’appareil
Back Wall To Flue Pipe / Entre tuyau et le mur arriere
Side Wall To Flue Pipe / Entre tuyau et le mur lateral
14
17
17-1/2
26-3/4
330
432
444
679
Walls to Unit Body / Entre mur adjacent et l’appareil
Walls to Flue Pipe / Entre tuyau et le mur adjacent
F
E
Corner Installation
Inches Millimeters
14
21-3/4
330
552
G
G
H
J
Floor protection must be a minimum 3/8” (9.5mm) of 0.84k material, or
0.45R. Must also be placed under any horizontal sections of flue connector,
extending 2” (51mm) beyond the measurement of the pipe. Use of bottom
heat shield required on protected floor.
Pour protéger le plancher, il faut sous le poêle un matériau (9.5mm / 0.84k),
o 0.45R. qui doit aussi être placé sous les parties horizontales du tuyau
de raccord à la cheminée et s’étendre à 51 mm (2 po) au-delà de la mesure
du tuyau.
Sides / Côtés
Front- from glass/Devant, par rapport au verre
Rear / Arrière
J
H
G
Floor Protection Requirements
Inches Millimeters
8
18
8
203
457
203
Date of Manufacture / Date de fabrication:
2015 2016 2017 JAN feb mAr Apr mAy JUN JUl AUg sep OCT NOV DeC
Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032